PX2-1 series with Ex db protection for Zone 1 and 2
PX2-2 series with Ex nA protection only for Zone 2
Designed for the continuous monitoring of the ambient air to detect combustible gases and vapors for use in the hazardous areas of zones 1 and/or 2 according to Directive 2014/34/EU.
Microprocessor-based gas sensor with 4–20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors by means of an infrared or catalytic sensor element (Pellistor).
The calibration of sensors without an LCD display is carried out via the calibration device STL06-PGX2 or the PC soft-ware PCE06-PGX2. Sensors with LCD display have an integrated calibration routine that is started from the outside by a permanent magnet without opening the housing. In case of an alarm or failure the backlight of sensors with LCD display changes from green to red.
FEATURES:
ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
Enclosure: additional CSA certificate for Class I, Div. 1
μGard®2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect O2 Toxic gas.
The MC2-X-E1195-X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical O2 sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
Digital measurement value processing incl. temperature compensation
Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
High accuracy, selectivity, and reliability
Low zero point drift
Sensor life time: Refer the datasheet
SIL2 Compliant development process
Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
Reverse polarity protected, overload and short-circuit proof
Integrated heating down to -35°C
Optional:
Without housing
With housing Plastic: Type D, 94 x 65 x 57 mm
4-20 mA output signal
2-10 V output signal
With display for values and operation, 2x open collector for horn and warning lamp
Conformity to: o EN 378 o EN 45544 o EN 50104 (for O2) o EN 50271 o EN 50545 o EN 61010-1 o ANSI/UL 61010 1 o CAN/CSA-C22.2 No. 61010-1 • Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Oxygen Gas Detector and Monitor ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Oxygen (O2) Gas Detector and Monitor. We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, … Continue reading “Oxygen Gas Detector and Monitor”
Under the current pandemic of CORONA VIRUS (COVID -19) affecting nearly every country in the world, health officials are releasing daily updates and guidelines to combat the virus, hence we are here to support by strongly recommending of installation of the Oxygen sensors inside Makeshift Hospitals and Hospital Wards to ensure oxygen enrichment is controlled, … Continue reading “Oxygen(O2) and Carbon Dioxide(CO2) Gas Monitor in Makeshift Hospitals and Hospital Wards”
We are pleased to inform you all that recently we have supplied our product and service to Eternal Heart Care Center (EHCC – Eternal Multispecialty Hospital Jaipur ), where we supplied MSR Oxygen Sensor Transmitter – MC2-D-E1195-A-3-0 and Oxygen Gas Leak Control and Display Alarm Panel for there Oxygen and NO Cylinder storage Room. We are … Continue reading “Oxygen Sensor Transmitter For Hospital’s Oxygen Cylinder Storage Area”
We are pleased to introduce Oxygen Sensor Transmitter – MC2-D-E1195-A-3-0, German Technology with high accuracy , long life, easy maintenance in economical price . Oxygen (O2) gas detectors are used for the detection of oxygen in rooms where changes of the oxygen concentration are possible, such as laboratories, hospitals and food process, cold storage and fruit ripening … Continue reading “Oxygen Sensor Transmitter – MC2-D-E1195-A-3-0”
Oxygen (O2) gas detectors are used for or the detection of oxygen in rooms where changes of the oxygen concentration are possible, such as laboratories, hospitals and food process industries etc. Alarm limits for decreasing concentration of gas is set to 18-19% Vol. Other reasons why oxygen levels can fall are among others: Combustion of … Continue reading “Oxygen (O2) Gas Detector”
ALVI AUTOMATION INDIA PVT LTD (www.alviautomation.com) a Div of ALVI TECHNOLOGIES PTY LTD(www.alvi.com.au) also trading as GasAlarm Systems(www.gasalarm.com.au) presents cutting edge German Technology , Greisinger- Dissolved oxygen sensor transmitter Model no OXY3610MP-A1-L04 The OXY 3610 MP measures the oxygen concentration in liquids. The device can be used in aquaristics, fish farming as well … Continue reading “Greisinger-Dissolved oxygen sensor transmitter OXY3610MP-A1-L04”
Exchangeable sensor unit including digital value processing, temperature compensation and self control for the continuous monitoring of the ambient air. The sensor unit MC2 houses a module with μController, analog output and power supply in addition to the electrochemical sensor element including amplifier. The μController calculates a linear 4 – 20 mA (or 2 – … Continue reading “MSR Germany Toxic gases and oxygen with analog output”
ALVI Automation – India (http://www.alviautomation.com) in association with Gas Alarm Systems – Australia (http://www.gasalarm.co.au) offer MSR Germany PolyGard® Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and internal buzzer for the continuous monitoring of the ambient air and detecting toxic … Continue reading “MSR Germany PolyGard® Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen”
ALVI Automation India (www.alviautomation.com) in association with Gas alarm systems, Australia(www.gasalarm.com.au) http://www.alvitech.co.auare pleased to offer PolyGard® Standalone SPC-X3-11XX for Pollution / Emission Moniotor ,Toxic Polluting gases and vapours including oxygen Detector Sensor. DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and internal buzzer for the continuous monitoring of the ambient … Continue reading “PolyGard® Standalone SPC-X3-11XX for Pollution / Emission Moniotor ,Toxic Polluting gases and vapours including oxygen Detector Sensor”
µGard®2 Oxygen Gas Transmitter MC2-X-E1195-X-X GasAlarm
µGard®2 (developed by MSR) is the new exchangeable sensor unit which is capable of digital value processing, temperature compensation and self control for the continuous monitoring of the ambient air to detect O2.
The MC2-X-E1195-X-X is a sensor element at its core with many possible customization's. The beauty of the microgard 2 system is a micro controller integrated into the Electrochemical O2 sensor module. The Electrochemical measurement principle with the integrated temperature compensation ensures highest accuracy, selectivity and reliability despite the long calibration interval. The micro controller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Electrochemical sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
Digital measurement value processing incl. temperature compensation
Data / Measured values stored in the micro controller on the sensor unit allowing easy swap of a old sensor with a newly calibrated sensor.
High accuracy, selectivity and reliability
Low zero point drift
Sensor life time > 15 years
Easy maintenance and calibration by exchange of the sensor module or by integrated on-site calibration.
4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
Reverse polarity protected, overload and short-circuit proof
Integrated heating down to -35°C
Optional:
Without housing
With housing Plastic: Type A, 90 x 130 x 57 mm IP65
4-20 mA output signal
2-10 V output signal
Built for a standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
IECEx Oxygen Gas Transmitter PX2-X-X-E1195-B PolyXeta II.
Microprocessor based analog gas transmitter with 4–20 mA output signal for monitoring the ambient air and detecting toxic concentrations (0 – 21 %Vol) by means of a catalytic sensor (Electro-chemical). The MSR gas transmitter is used to detect combustible and toxic compounds in areas classified as Group I.
Features
(0) 4-20 mA analog signal output
Comes in sealed unit which is safe for opening in Zone 1 without switching off.
IECEx Certification MSR Electronic
The sealed version option allows opening of case while in operation in hazardous area.
SIL 2 Certification for RS485 / 4-20 Analog / Relay for safety functions
ATEX Certifications MSR Electronic
Continuous Monitoring
Microprocessor with 12 bit converter resolution
Self diagnostic procedure
Easy Calibration, housing can be opened in zone 1, during operation.
Reverse Polarity / Overload Proof
Certified for Zone 1 / Zone 2
Optional Extras:
LCD display
Relay Set & LCD
Relay Set
Built for a standard output of 4-20 mA analog signal output, this transmitter is compatible with the PolyGard series controllers the MGC/DGC as well as any other electronic control or automation system.
IECEx Oxygen Gas Transmitter PX2-X-X-E1195-A PolyXeta II.
Microprocessor based analog gas transmitter with 4–20 mA output signal for monitoring the ambient air and detecting toxic concentrations (0 – 25 %Vol) by means of a catalytic sensor (Electro-chemical). The MSR gas transmitter is used to detect combustible and toxic compounds in areas classified as Group I.
Features
(0) 4-20 mA analog signal output
Comes in sealed unit which is safe for opening in Zone 1 without switching off.
IECEx Certification MSR Electronic
The sealed version option allows opening of case while in operation in hazardous area.
SIL 2 Certification for RS485 / 4-20 Analog / Relay for safety functions
ATEX Certifications MSR Electronic
Continuous Monitoring
Microprocessor with 12 bit converter resolution
Self diagnostic procedure
Easy Calibration, housing can be opened in zone 1, during operation.
Reverse Polarity / Overload Proof
Certified for Zone 1 / Zone 2
Optional Extras:
LCD display
Relay Set & LCD
Relay Set
Built for a standard output of 4-20 mA analog signal output, this transmitter is compatible with the PolyGard series controllers the MGC/DGC as well as any other electronic control or automation system.