Gas Detectors for Jewellery Manufacturing & Polishing Industries.

Jewellery manufacturers are increasingly worried about their worker’s health and safety conditions, Most jewellery companies want to prevent work-related illness and injury, and they also want to prevent pollution from their manufacturing processes, we have Smart Gas Detectors for Jewellery Manufacturing & Polishing Industries.

Most of the gases/solvent acid used or generate during the Jewellery polishing, Soldering, Dewaxing,  process are like Cyanide, Hydrogen Cyanide, Hydrofluoric acid  Sulphur dioxide , Nitric Oxide, Hydrochloride, Methyl Chloride, Cadmium, Acetone, Hydrogen Methane.

These gases or it’s vapour are very dangerous for human health, may cause Lungs cancer, Blood Cancer, Kidney, Liver damage, Cyanide gases are very dangerous for human life sometimes cause instant death.

Since it comes under critical Human Life Safety, it is very important to Install authenticated, Gas Detection and Control Monitoring systems in the areas where these dangerous gases or solvent are used, so that it can be monitor, control & provide safe area to Work, definitely it will increase your productivity too when your worker do their work with secure mind.

We can help you in all your safety automation, gas detection needs, please feel free to contact us anytime at INFO@ALVIAUTOMATION.COM +91-7091777274

Toxic Combustible Refrigerant Fixed Gas Detection Systems

German Technology and German quality is the best in the World, we are pleased to introduce that we too offering the best German technology for Fixed  Gas Detection systems & Instrumentation Solutions for critical life safety and assets protection and enhancement from all types of Toxic (CO, CO2, Ethylene, Oxygen, Ammonia, CL2, NO2, O3, So2, H2S, HCN Gas )  Combustible (H2, LPG, Petrol Diesel Vapor, Methane, Methyl Ethyl Ketone, Propane, Acetone Methanol Gas) Refrigerant (R134a, R410a, R32, R434a,  R123, R22, etc.. Gas) gas leakage.

 Fixed Gas Detection systems provide continuous monitoring to the facilities and alert the responsible person immediately to prevent any hazardous incident.

A permanent gas detector enhances workplace safety and prevents loss of productivity due to leakage or accidents.

For more Details Please feel free to contact us anytime  – Info@alviautomation.com

Carbon Monoxide (CO) Detector for Basement Car Parking

When it comes to Carbon Monoxide (CO) Detector for Basement Car Parking to control & operate the Jet, Fresh air, Exhaust automatically  MSR Germany/GASAlarm make  Compact GAS-CO-300-D model is the Best techno-commercial option in the International HVAC market, having following features.

SPECIFICATIONS:- 

  • Sensor Model Available in Stock: – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 30 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in: IP65 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 935m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output, also available in 2-10VDC
  • Flammability: – UL 94: V2
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval:  CE/ UL Enclosure.

For More details & enquiry please contact – Info@alviautomation.com

Refrigeration Gas Detection & Control Systems

We are pleased to introduce our Refrigeration Gas Detection & Control Systems, we provide solutions for Refrigerant Gas depending on the customer’s & site’s requirement so that our systems meet your site demands.

We have all types of refrigerant gas solutions Like- R32, R134a, R410a  R23,  R508b, R1234yf, R452a, R513a, R454c, R455a, R454b,R1234ze,R123 , R22 , R401a ,R401b , R402a , R402b, R403a , R408a ,R409a ,R411a  R134aR407a  R416a  R417a R422a R422d R427a  R437a, R438a,R449a, R407f, R450a ,R125 , R32, R404a, R407c ,R410a, R434a ,  R507a , R448a , R452b, R143

Why Refrigeration gases required   – It is used to reduce the temperature of the environment or any liquid, products by mechanical or vapor compression process.

Few Refrigerant Gases are Toxic in nature and few are highly combustible that is why Industries need to install Refrigeration Gas Detection & Control Systems in their premises for the safety of humans, assets, money & energy saving from unwanted gas leakage.

All Refrigerant products comply with and even exceed the new European standard EN 378.

FEATURES

  • Digital measurement value processing
  • Internal function control with integrated hardware watchdog
  • Data / measured values in μC of the sensor unit, therefore simple exchange
    uncalibrated <> calibrated
  •  High accuracy, selectivity, and reliability
  •  Low zero point drift
  •  Long sensor lifetime
  • Hardware & software according to SIL2 compliant development process
  •  Easy maintenance and calibration by the exchange of the sensor unit or by comfortable on-site calibration
  • 4 – 20 mA (or 2 – 10 V) analog output with selectable signal output for special mode, fault, etc.
  • Reverse polarity protected, overload and short-circuit proof
  •  Housing for the integration of the sensor unit
  •  IP 65 version
  •  Display (option)
  •  Display with two open-collector outputs for horn (resettable) and warning lamp(option)
  • Conformity to
    o EN 61010-1
    o ANSI/UL 61010 1
    o CAN/CSA-C22.2 No. 61010-1)
    o EN 378
    o EN 61508-1-3
    o EN 45544-1
  •  Duct mounting kit (accessory)

20190412_120158

csm_ARB2_fdb399c608

For More Information please feel free to contact us and write us to info@alciautomation  

Industrial Gas Detection Systems

We ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Industrial Gas Detection Systems, Sensor Detection Systems detects monitor and send the output to  Control Alarm systems for controlling the leakage, to protect the lives and assets.

We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

Description:

All Toxic & Combustible Gas  detector is a highly robust, industrial grade, flameproof/ Explosionproof  Gas Leakage Detection Systems.

The detector is used for online, continuous monitoring of the flammable concentration of Methane Gas in PPM or %Vol terms in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

With Benefits:

  • ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  • Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  • For zone 1 (and also suitable for zone 2) Type “Ex db” with flame-proof enclosure
  • For zone 2: Type “Ex nA” with flame-proof enclosure
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  • Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control center
  • Reverse polarity protection
  • Overload protection
  • LCD with status LEDs (optional)
  • Alarm and fault signal relay (optional)

Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts to info@alviautomation.com

Be sure, Be safe – Gas Detectors and Alarm System

Nonane Gas Detector and Monitor

Nonane Gas Detector and Monitor 

ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world-class cutting edge Nonane(C9H20) Gas Detector and Monitor.

We are involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

Description:

Nonane(C9H20) detector is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Nonane(C9H20) Gas leakage detection or PPM monitoring.

The detector is used for online, continuous monitoring of the flammable concentration of Methane Gas in PPM or %Vol terms in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

With Benefits:

  • ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  • Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  • For zone 1 (and also suitable for zone 2) Type “Ex db” with flame-proof enclosure
  • For zone 2: Type “Ex nA” with flame-proof enclosure
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  • Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control centre
  • Reverse polarity protection
  • Overload protection
  • LCD with status LEDs (optional)
  • Alarm and fault signal relay (optional)

Our Industries:
Our customers come from various industries like oil/gas, chemical, manufacturing, petrochemical, pharmaceutical, building, mining, nuclear, steel, defense, power, water, wastewater, mining, cement, dairy, automobile, etc.

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts to info@alviautomation.comsales@gasalarm.com.au

Be sure, Be safe – Gas Detectors and Alarm System

Gas Detection & Control Monitoring Systems

Gas Detectors are used to measure and indicate the presence of various gases present in air or environment, Gas Detection & Control Monitoring Systems can be used as an early gas detection systems against the increase in the concentration of life and assets-threatening gases such as carbon dioxide (CO2)carbon monoxide (CO), ammonia (NH3), H2S, SO2, NO, NO2, Ethylene and combustible gases like CH4, Hydrogen, LPG, CNG, PNG, petrol Diesel Vapour, 

Large number of industries are involved in the use of combustible and toxic gases or produce high levels of CO, CO2 or gases such as SO2, CH4, H2, Petrol/Diesel, etc and their random escape may sometimes lead to the increase in the concentration of these gases which creates a potential hazard for manpower and surroundings but by installing  World-Class best MSR Germany Gas Detection & Control  Monitoring Systems one can control all these hazardous incident.

World Class Best MSR Germany Fixed gas detector options are ideal for monitoring gas concentration levels in industrial environments or specific location and are installed to measure oxygen, toxic gas, and combustible gas, in a place where a potential gas hazard exists.  It shows not only the concentration of gas but also the diagnostic result of the unit itself through the LCD display and can be connected to a controller with a standard 4-20mA analog output communication or RS-485 digital communication for direct display at the control room.

For more details and product demonstration please click here 

CO Sensor for VFD & Exhaust Fan Operation in Basement Car Parking

Our World Class Best German GAS-CO-300-XX,  CO Sensor for VFD & exhaust fan operation in basement Car parking, a sensor is used to detect the level of CO and give output signal. The number of required sensors is decided based on the size of the area or car park. All sensors will be wired to the common PLC panel for VFD and Exhaust Fan operations.

CO Detector can detect various types of smoke, Smoke radicals, and fumes. The sensors can be programmed to generate alerts if the level of CO exceeds the permitted level of ppm set. A control signal can be generated by the sensor which then is utilized to operate exhaust fans, VFD, Fresh Air Fans, and also Audio Visual Alarm. If the sensors detect that the level of CO has exceeded the permitted levels, the exhaust fans will be switched ON immediately to remove the contaminated air from the area and to bring fresh air.

Our CO Sensor for VFD & exhaust fan operation in Basement Car Parking  Can Detects :- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smoldering fire and smoke detection.
  • VESFA system (very early smoke and fire alarm)

Gas-CO-300-XX SPECIFICATIONS:- 

  • Sensor Model Available in: – Gas-CO-300-XX
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 50 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in IP65
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 935m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output, also available in 2-10VDC
  • Flammability: – UL 94: V2
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval: EMC Directives 2004/108/EC, EN 61010-1:2010/CE

For more details please watch simple Demo – ClickHere

Experience the Best Carbon Monoxide Detector

Carbon Monoxide Sensor Transmitter with enhanced CO Gas radicals detection capability

We are pleased to mention that our word-class best CO – Carbon Monoxide detectors are installed in many reputed projects of Basement Car Park Ventilation Systems all over the world and India (like Lucknow High Court, Delhi District Court, ITO Delhi, Elante Mall, South City Mall, Centre Square Mall, DLF Camalies, DLF Horizon, DLF Crest, DDA Narela, DDA Sultan Grahi  DLF Chennai, Indian Army, Indian Navy, RBI, etc)

Make:- MSR Germany/GasAlarm

Area Of Application:-                        

Ideal for :
Parking area, garages, chiller rooms, and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points:- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smoldering fire and smoke detection.
  • VESFA system (very early smoke and fire alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in : – Gas-CO-300-X
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 50 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in IP65
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 935m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output, also available in 2-10VDC
  • Flammability: – UL 94: V2
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval: EMC Directives 2004/108/EC, EN 61010-1:2010/CE

For Technical Datasheet please click here