Fischer DP Gauge for Process, Chemical Application – DA03
By ALVI- Adjustable limit contacts: delayed action or magnet actuated type
- Proximity type (NAMUR) non-contact limit detector
- Pointer position transducer, with electrical signal output
Applications:
- Chemical, pharmaceutical industries
- Process industries
- Marine and off-shore
- heavy industries
- power plants, hydro plants
- petrochemical, oil & gas
- refrigeration, building
- fertilizer, transportation
Features:
- Corrosion resistant
- Rugged, wear resistant mechanism
- Unaffected by fouling
- Easily cleaned pressure chamber
- Measuring ranges: 0-40 mbar to 0-25 bar
- Nominal pressure rating: 40 bar or 100 bar (max. static pressure)
- Accuracy: ± 1.6% of span
- Max. differential overpressure:Safe up to max. static pressure; pressure differential in either direction
- Indicator:Circular dial type, 100 mm or 160 mm diameter
- Operating temperature: Ambient: -20°C to +80°C, Media: +100°C, maximum
- Temperature coefficient: Approx. 0.3% / 10°C
- Zero adjustment: Screw through hole on top of dial housing. ±25% FS.
- Protection class: IP 54, per DIN EN 60529
- Pressure chambers: Smooth internal surfaces without recesses; flush sensing diaphragms; easy to clean
- Pressure connections: DIN EN 61518 connecting flanges with 2x G½ (F) threaded sockets. Various bite type ferrule connectors (see Ordering Code)
- Purge ports: 2x G 1/8 (F) threaded sockets, in flanged pressure chamber casing; screw plugs fitted
Type “R”:
- Pressure chamber (wetted part): Stainless steel 1.4404 (AISI 316L)
- Diaphragm (wetted part): dP ≤ 400 mbar: stainless steel 1.4571
- dP ≥ 0.6 bar: DURATHERM® (stainless steel)
Type “H”:
- Pressure chamber (wetted part): Hastelloy® C4
- Diaphragm (wetted part): dP ≤ 2.5 bar: Hastelloy® C 276
- dP ≥ 4 bar: Standard diaphragm with separating foil made from Hastelloy® C 276
- NB: Models with separating foil not useable for vacuum application.
- Intermediate plate: Aluminium alloy (AlMgSiPb); hard coated
- Dial mechanism, gauge housing: Stainless steel 1.4301
- Dial window: Laminated safety glass
- Dial scale and pointer: Aluminium
- O-ring gasket: Viton® (FKM, fluorocarbon elastomer)
Electrical accessories: Limit signalling contacts: delayed action / magnet actuated switch type / non-contact proximity type limit detector. Pointer rotation transducer: capacitance type, with output signal proportional to the pointer position (uses deeper gauge housing: see Dimensions). For details of electrical accessories, see Data Sheet KE. Liquid filling For operating conditions involving vibration, pressure fluctuations, and/or moisture condensation inside, the gauge can be supplied with glycerine filling. Reference pointer Adjustable pointer for visual marking of limit / reference value. Peak registering pointer Separate pointer without spring, friction holding: dragged by the measuring pointer as the measured value increases. Stays put when the measuring pointer recedes, thereby registering peak value. Manual re-setting. Options (on special order) Special materials: PTFE coated or Hastelloy-C diaphragm and pressure chamber casing.