Enhanced CO gas radicals detection by VEFSA – Carbon Monoxide Sensor Transmitter for Very Early Fire Smoke Alarm Systems very useful for CO Car Park Monitoring /Ventilation Fan control, also meeting following standards:
AS 1668.2 mechanicalVentilation
Pollution & Emission Control
Green House Gas Saving
Also, save Energy for Next Generation
Very Eary Fire & Smoke Alarm
Useful for the protection of Human life Building, Basement, Plant, Industries.
Our Gas-CO-300-D CO Gas Detector/Sensor Transmitters is capable to detect and measure CO, Smoke & CO+ Enhanced Gas radicals (Fumes before the fire smoke begins)
Gas CO, Carbon Monoxide Sensor Transmitter comes with typical measuring range of 0-100ppm, 0-300ppm, 0-500ppm, having gel-type Electrochemical sensor cell (without any orientation problem), GAS-CO-300-D Sensor Transmitter is a highly responsive, high accuracy, fast repeatability & high-reliability, user friendly, easy to use model.
Gas-CO-300-D model VEFSA Carbon Monoxide Sensor Transmitter has a coverage area of 465 Sqm to 936Sqm.
Gas-CO-300-D model VEFSA CO Sensor Transmitter gives analog output 4-20mA or 2-10V, need supply power of 24VDC.
For more details and enquiry please feel free to contact us anytime at – Info@alviautomation.com
Carbon Monoxide (CO) and Nitrogen Dioxide (NO2) as per National Building Code (NBC) are most commonly and widely used gas sensor for basement car park application to detect the accumulation and increase in CO and NO2 gas concentration exhausted from petrol and diesel powered vehicles and locomotives. Our main objective as per Global standards is the dilute the gas concertation by means on purging fresh air and simultaneously exhausting the accumulated toxic gases with the help of Supply and exhaust air fans along with the dual speed Impulse fans (JET air fans) to distribute the air across the entire basement area.
As per European Standard acc. To EN 50545-1 and as per ASHRAE Standard 62.1, CO and NO2 gas sensor are intended to control a ventilation system and/or to give an indication, alarm or any other signal to warn of a toxic hazard. These gases are generically called “target gases, apart from these gases LPG, CNG (CH4) and Hydrogen (H2) are the other probable gases entitled in the car park basement application from LPG, CNG powered up vehicles along with latest battery operated/hydrogen fuel cell/hybrid technology vehicles which are highly flammable/combustible in nature and can result in a catastrophic disaster if not detected/identified at the early stages for critical life safety and asset protection which could also become the main source of fire.
For a futuristic Visionary Basement ventilation car park solution, we should adopt the following gas type such as CO, NO2, LPG, HC (CNG and H2) gases along with smart digital control system where the Gas Detectors shall be connected in a daisy loop fashion as shown below:
Here the traceability of the gas sensors and identification of the fault error signals becomes very easy compared to the conventional method of direct coupling of analog signal from each gas sensor making the system more complex, bulky and expensive.
Australian standard AS 1668.2-2012 and Building Code Australia Section “J” indicates that the ventilation of the parking structures should be continuous, 24/7. However, by ventilating only when the sensors indicate a requirement, energy can be conserved both from reduced fan operation and also from any related heating or cooling costs and CO gas radical’s detection for enhanced Very Early Fire Detection
The selection of CO sensor being the most common gas found in car park basement application also plays a vital role to achieve the energy saving and make the entire system more efficient and reliable with linear variation to detect not only just CO gas but to also detect enhanced CO gas radicals having detection capability for very early smouldering fire and smoke detection (product of gas radicals generated due to products of combustion fire)
Carbon monoxide and early smoke & fire sensor transmitter Technical Data and Specifications: (for Basement car park ventilation, enhancing gas radical CO detection for early fire and smoke due to products of combustion and smouldering fire in building application)
• Capable of detection, measurement and monitoring of carbon monoxide and carbon monoxide gas radicals • Electro-chemical type sensor cell, Electrochemical Diffusion, Electrolyte type Gel based. • Gel based Electrolyte and Hydrophobic filter in the sensor cell • 0-300ppm measuring range, taking care of over range detection. • Sensor coverage area: 465 m2 to 930 m2 • High accuracy, high repeatability, high reliability • 2-wire loop powered connection for power supply and signal output. • Analog output: 4-20mA (standard), 2-10V (optional) • Modbus output • Spring loaded terminal • Operating temperature: -15 0C to +50 0C • Humidity: 10-95% RH (non condensing) • Mounting height: 1.5m – 1.8 m • linear, proportional analog output • Low response time ≤ 10 sec • Accuracy: ± 3 PPM • Low warm up time, ≤ 1 mins • Low voltage operation: 24VDC • Low power consumption: 22 mA, max. (0.5 VA @ +24VDC) • Not cross-sensitive to gases like SO2, Acetone, Ammonia, Carbon Dioxide, Nitrogen dioxide, Nitric Oxide. • Wall mountable without need of further mounting brackets. • Plug-in, easy replaceable sensor unit for easy service and replacement (no need to change the whole unit) • Manual trimpot and digital type calibration facility, with annual calibration frequency • Auto recovery to zero point. • Life expectancy of > 6 years to 10 years • Capable of mounting in any direction, with no effect on performance, output and life of these sensors (no orientation problems) • Poisoning protection, against background gases, lead vapours, dust etc • Over flooding protection • Reverse polarity and short circuit protection • Simplified maintenance via exchange of pre-calibrated sensor cartridges or easy on site-calibration • IP65 protected housing, with provision of dust and moisture protection with hydrophobic filter arrangement. • Tough, rugged, glass-fibre reinforced, Impact resistant, fully gasketed polycarbonate IP 65 enclosure • IMMUNITY TO RF/FM INTERFERENCE as per the guidelines of EMC- Directive 2004/ 30/ EU. • Compliance to CE and UL standards, EMC Directives 2014/30/EU, IP 65/66 (EN 60529/ DIN VDE – 0470-1), Impact Resistant IK08 (DIN EN5012/VDE 0470 segment 100), UL508 & CSA C22.2 No. 14-13Certified Enclosure for IndustrialControl Equipment, UL50 & CSA 22.2 No. 94.1-07 Certified Enclosure for Electrical Equipment. • Enclosure flammability in accordance to UL 94: V2.
Toxic (NO2, O2, SO2 etc) gas sensor transmitter Technical Data and Specifications:
• Electro-chemical type sensor cell • Gel based Electrolyte and Hydrophobic filter in the sensor cell • High accuracy, high repeatability , high reliability • 3-wire loop powered connection for power supply and signal output. • Analog output: 4-20mA (standard) or 2-10V • Modbus output • Operating temperature: as per gas type • Humidity: as per gas type • Mounting height: as per gas type • linear, proportional analog output • Low response time: as per gas type • Accuracy as per gas type of measuring range. • Low warm up time: as per gas type • Low voltage operation: 24VDC/VAC • LCD Display: Two lines, 16 characters each, monochrome (Optional) • Open-collector (transistor) output (Optional) • Low power consumption: 23 mA, max. (0.6 VA for 24V) • Not cross-sensitive to gases: as per gas type • Wall mountable without need of further mounting brackets. • Plug-in, easy replaceable sensor unit for easy service and replacement (no need to change the whole unit) • Digital type calibration facility, with annual calibration frequency • Auto recovery to zero point. • Life expectancy: as per gas type. • Capable of mounting in any direction, with no effect on performance, output and life of these sensors (no orientation problems) • Poisoning protection, against background gases, lead vapours, dust etc • Over flooding protection • Reverse polarity and short circuit protection • Simplified maintenance via exchange of pre-calibrated sensor cartridges or easy on site-calibration • IP65 protected housing, with provision of dust and moisture protection with hydrophobic filter arrangement. • Tough, rugged, glass-fibre reinforced, Impact resistant, fully gasketed polycarbonate IP 65 enclosure • IMMUNITY TO RF/FM INTERFERENCE as per the guidelines of EMC- Directive 2004/ 30/ EU, CE • Compliance with according EN 378, EN 45544-1, EN 50104 (for O2, EN 50545, EN 50271, EN 61010-1, ANSI/UL 61010 1, CAN/CSA-C22.2 No. 61010-1 • Device flammability in accordance to UL 94 V2
LPG, CNG, Hydrogen (H2) sensor transmitter Technical Data and specifications:(Also Applicable to all Combustible/Flammable type gas sensor transmitter)
• Catalytic (pellistor) based sensor cell, with catalytic bead • Measuring range: 0-100% LEL (lower explosive limit) for flammability monitoring with no poisoning effect of background gases • Catalyst capable of providing flashing point, at lower temperature, for the sensor cell. • Microprocessor based value processing with temperature, vibration, moisture, humidity etc compensation reading • High accuracy, high repeatability , high reliability • 3-wire connection for power supply and signal output. • Selectable analog output: 4-20mA or 2-10V. • Modbus output • Accuracy: ± 1 % LEL • Linear and proportional signal output. • Hardware & software according to SIL2 compliant development process • Low response time: t50 < 3 s; t90 < 15 s • Low voltage operation: 24V AC / DC • Low power consumption: 75 mA, max. (1.8 VA for 24V) • Easy maintenance and calibration by exchange of the sensor unit or by comfortable on- site calibration • Wall mountable without need of further mounting brackets etc. • Plug-in, easy replaceable sensor unit for easy service and replacement (no need to change the whole unit) • LCD Display: Two lines, 16 characters each, monochrome (Optional) • Open-collector (transistor) output (Optional) • Life expectancy of > 3 years • Capable of mounting in any direction, with no effect on performance, output and life of these sensors (no orientation problems) • Poisoning protection, against background gases, lead vapours, dust etc • Over flooding protection • Reverse polarity and short circuit protection • Digital type calibration facility, with annual calibration frequency • Capable for field calibration • IP65 protected housing, with provision of dust and moisture protection with hydrophobic filter arrangement. • Tough, rugged, glass-fibre reinforced, Impact resistant, fully gasketed polycarbonate IP 65 enclosure • Vibration protection (High frequency, low amplitude) and knock protection (high amplitude, low frequency) • Fast response time • IMMUNITY TO RF/FM INTERFERENCE as per the guidelines of EMC- Directive 2004/ 30/ EU, CE • Compliance with according EN 50271, EN 50545:2017, EN 61010-1, ANSI/UL 61010 1, CAN/CSA-C22.2 No. 61010-1 • Device flammability in accordance to UL 94 V2
Globally “Best Selling ” Carbon Monoxide Detector GAS-CO-300-D “on-sale ” for the limited period till stocks clear.
German Made GasAlarm model number- GAS-CO-300-D Carbon Monoxide Sensor Transmitter having an excellent high-quality Electrochemical Sensing technology, Top Measurement accuracy, fast response, long service life sensor, two core wiring connection, up to 80% energy-saving, protection class IP65 in economical discounted price range.
Ideal for :
Basement Car Parking area, garages, chiller rooms, and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.
Key Points:-
Carbon Monoxide with enhanced CO radical detection capability
Very early smouldering fire and smoke detection.
VESFA system (very early smoke and fire alarm)
SPECIFICATIONS:-
Sensor Model Available in: – GAS-CO-300-D
Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
Measuring Range: – 0-300 ppm (Standard)
Connection: – Two
Response time T90:- ≤ 50 Sec
Warm-up time (First Time):- ≤ 3 Min.
Protection Class Available in IP65
Stability & resolution: – ± 3 ppm
Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 11 Years )
Calibration Interval: 1 Year.
Sensor Coverage Area: – 700 m2 to 750m2, ideal condition.
Humidity non-condensing : 15-90% RH
Working temperature:–10°C to 50°C
Power supply:- 18 – 28 VDC ( Overload protected)
Analog output signal:- Standard: 4-20 mA Linear Output
Warranty: 12 Month only on manufacturing defects
Guidelines Approval: CE, UL
Please watch simple demo of our Gas leak Control and Monitoring System click here
We ALVI Automation India Private Limited in association with GasAlarm Systems Australia (www.gasalarm.com.au) and MSR Germany, specializing in gas detection & monitoring solutions feel pleased to say that we had done lots of successful car park ventilation system projects all over India as well as in Australia, Newziland, Sri Lanka, Myanmar, Canada, UAE, and many more countries and found our Carbon Monoxide Sensor Transmitter GAS-CO-300-D and MSR CO Sensor Transmitter MA-0-1110-F-B is the best energy saving, accurate, fast responsive, long life and economical in cost compared to the other brands present in market .
Introducing the GasAlarm Systems GAS-CO-300-D
Most cost optimum sensor transmitter for carbon monoxide – application in car park ventilation fan control, coal mining, coal handling plant, coal washeries, boilers, steel plants, pharmaceutical anywhere gas and coal combustion take place – best very early fire detection due to gas radicals detection – smoldering fires.
Specifications in Detail:
24VDC power with 4-20mA output (current loop)
0-300PPM Carbon Monoxide measuring range
Long Life – ≥ 6 years (Life Expected ≥ 10 years)
High Accuracy – ± 3ppm
Wiring – 2 wire system (reduce wire cost)
Onboard potentiometer for “zero” adjustment
Onboard potentiometer for “gain/span” adjustment
Multimeter connections for measurement during calibration
When it comes to Carbon Monoxide Detection in Car Park Ventilation Systems, Our European Standard MSR CO Sensor Transmitter have great demands in global market.
Now available with special promotional discounted price for Indian market with following details :
Ideal for :
Parking area, garages, chiller rooms and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.
Key Points :-
Carbon Monoxide with enhanced CO radical detection capability
Very early smouldering fire and smoke detection.
VEFSA system (very early fire and smoke alarm)
SPECIFICATIONS:-
Sensor Model Available in Stock : – MA-0-1110-F-B
Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel based (no leak, no membrane rapture, no orientation problem & no false alarm)
Measuring Range: – 0-300 ppm (Standard)
Connection: – Two and Three wire sensor
Response time T90:- ≤ 50 Sec
Warm-up time (First Time):- ≤ 3 Min.
Protection Class Available in : IP44/54/65/66 (Flameproof and weatherproof )
Stability & resolution: – ± 3 ppm
Sensor life expectancy:- ≥ 5 years (Site Feedback ≥ 10 Years )
Calibration Interval: 1 Year.
Sensor Coverage Area: – 700 m2 to 750m2, ideal condition.
Humidity non-condensing : 15-90% RH
Working temperature :–10°C to 50°C
Power supply:- 18 – 28 VDC ( Overload protected)
Analog output signal :- Standard: 4-20 mA Linear Output, also available in 2-10VDC
Carbon Monoxide Detector Transmitter is used to provide a proportional analog signal to the Multi-Input Control Panel or a Building Management System (BMS)
Ideal for :
Parking area, garages, chiller rooms and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.
Key Points :-
Carbon Monoxide with enhanced CO radical detection capability
Very early smouldering fire and smoke detection.
VEFSA system (very early fire and smoke alarm)
SPECIFICATIONS:-
Sensor Model Available in Stock : – MA-0-1110-F-B
Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel based (no leak, no membrane rapture, no orientation problem & no false alarm)
Measuring Range: – 0-300 ppm (Standard)
Connection: – Two and Three wire sensor
Response time T90:- ≤ 50 Sec
Warm-up time (First Time):- ≤ 3 Min.
Protection Class Available in : IP44/54/65/66 (Flameproof and weatherproof )
Stability & resolution: – ± 3 ppm
Sensor life expectancy:- ≥ 5 years (Site Feedback ≥ 10 Years )
Calibration Interval: 1 Year.
Sensor Coverage Area: – 700 m2 to 750m2, ideal condition.
Humidity non-condensing : 15-90% RH
Working temperature :–10°C to 50°C
Power supply:- 18 – 28 VDC ( Overload protected)
Analog output signal :- Standard: 4-20 mA Linear Output, also availabel in 2-10VDC
Low Pricing, Best Technology, High Accuracy, Long Life, Carbon Monoxide Gas Detector and Transmitter .
Benefits of CO Monitoring:
The very early sign in coal handling/processing plant fire is liberation of gas radicals (CO predominant). The idea is to detect the presence of this CO gas radical for very early fire prevention. By the time smoke is generated and detected it is already too late. A typical CO monitoring system for detection of products of combustion fires or spontaneous combustion of coal fires can warn potential fire two days in advance then flame is present or detected. By installing an effective CO and CH4 monitoring system, coal based power stations can benefit in the following ways:
Reduced insurance premiums
Better safety to plant and personals
Reduced down time
Prevention of loss of resources
Save time and money.
Why CO monitoring? :
Coal contains moisture which when liberated, coal gets oxidised, generating both heat and carbon monoxide. This heat when builds-up has the potential of creating spontaneous combustion of coal fires.
Coal is extremely friable and can be easily crumbled or pulverised. Further coal also generates coal dust needing extra preventive measures like proper maintenance of stockpiles, guarding against accumulations of coal in the fuel-handling system, compaction of stockpiles, cleaning spills and washing float dust. The most effective programme for fire-prevention would be to have Carbon Monoxide Monitoring and Control System
CO Monitoring Installation Aspects:
There will always be some safe background CO levels in coal handling or processing plants under normal operating conditions. These CO levels will rise during coal loading, handling and will again settle to normal levels once loading is finished and ventilation fans are running. It is important to find out the normal background CO levels by installing CO data-loggers and observing the CO generation trends under normal operating conditions of the plant. A typical CO level of 50 ppm of CO is normally present in background levels when coal is being handled, moved or transported. Based on these normal background CO levels the sizing/selection of the CO system (range etc) and alarm set points need to be undertaken.
Location of Sensors:
In general, it is wise practice to locate an adequate number of sensors at strategic locations based on knowledge of the potentials for ignition. When considering belt fires, sensors should be located in close proximity to drives, tail pieces, and main rollers.
When coal is the issue, any location where accumulation of coal dust or bulk quantities is likely or expected should be considered. These include belt transfers, crushers, dust collection systems, and storage bins (silos, bunkers, etc.). System Approach:
A typical system may consist of number of CO (range: 0-300, 500 or upto 1000 ppm) and or CH4 (range: 0-100% LEL) gas sensor/transmitters installed remotely at strategic potentially risky areas. The 4-20 mA output coming from these sensor/transmitters can be connected to a multi-channel gas controller which can handle from 2 to upto 96 remote sensor/transmitters. When CO concentration levels rise beyond the set limit (say above 100 ppm, depending on safe background levels), the built in relay contacts will automatically generate audio-visual alarm for plant supervisor to take corrective measure (ventilation fans, mains shut-off etc).