Ammonia Gas Leak Detection – Ammonia Sensor Transmitter

Ammonia is a Toxic, colorless and pungent smelling gas which affect living bodies,  to stop any hazardous and panic incident we must use Ammonia Gas Leak Detection – Ammonia Sensor Transmitter in the area where ammonia gas or gas container present.

Exposure to high concentrations of ammonia in the air causes immediate burning of the eyes, nose, throat and respiratory tract and can result in blindness, lung damage or death. Inhalation of lower concentrations can cause coughing, and nose and throat irritation to stop all these panic incident we need to use Ammonia Detector Transmitter in the place where there is a chance of leakage of NH3 ammonia gas.

This Ammonia Detector detects the leakage of ammonia gas and immediately and Transmit the signal to actuate the alarm and close the ammonia gas supply line.

Silent Features of MSR Ammonia Sensor Transmitter 

  • Measuring Range Available : 0-100, 0-300, 0-500 PPM
  • Gas Type: NH3 Ammonia
  • Sensor Cell: Electrochemical Diffusion
  • Operating Voltage: 24 VDC
  • Output Signal: 4-20 mA or 2-10 VDC
  • Response time T90 < 120 Sec
  • Housed in an IP65 polycarbonate Enclosure
  • Coverage area: 80-120 Sqm
  • Housing UL94 V2 approved
  • Wall mount housing
  • Calibration interval: 12 month
  • Continuous Monitoring
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Long life sensor
  • Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration
  • Software according to SIL2 compliant development process

For more Technical Details please click – Datasheet 

Carbon Monoxide Sensor Transmitter

We  ALVI Automation India Private Limited in association with  GasAlarm Systems  company based in Sydney, Australia (www.gasalarm.com.au) specialising in gas detection & monitoring solutions feel pleased to introduce our new and and best reliable Carbon Monoxide Sensor Transmitter  GAS-CO-300-X

Introducing the GasAlarm Systems GAS-CO-300-X

Most cost optimum sensor transmitter  for carbon monoxide – application in car park ventilation fan control, coal mining , coal handling plant, coal washeries , boilers , steel plants, pharmaceutical anywhere gas and coal combustion takes place – best very early fire detection due to gas radicals detection – smouldering fires.

 

Specifications in Detail:

  • 24VDC power with 4-20mA output (current loop)
  • 0-300PPM Carbon Monoxide measuring range
  • Long Life – ≥ 6 years (Life Expected  ≥  10 years)
  • High Accuracy –  ± 3ppm
  • Wiring – 2 wire system (reduce wire cost)
  • Onboard potentiometer for “zero” adjustment
  • Onboard potentiometer for “gain/span” adjustment
  • Multimeter connections for measurement during calibration
  • With “D” enclosure option, rated at IP65
  • With “F” enclosure option, rated at IP44
  • Calibration Interval – 12 Months
  • Easy to use with low maintenance  cost .

Click here to download the datasheet

For more query and enquiry please contact us : Info@alviautomation.com 

Ammonia Detector Transmitter

Ammonia is a Toxic, colorless and pungent smelling gas which affect  living bodies if ammonia gas present in air, to stop any hazardous and panic incident we must use Ammonia Detector Transmitter  in the primieces  where ammonia gas or gas container present .

Exposure to high concentrations of ammonia in air causes immediate burning of the eyes, nose, throat and respiratory tract and can result in blindness, lung damage or death. Inhalation of lower concentrations can cause coughing, and nose and throat irritation to stop all these panic incident we need to use Ammonia Detector Transmitter in the place where there is chance of leakage of NH3 ammonia gas .

This Ammonia Detector detect the leakage of ammonia and immediately and Transmit the signal to actuate  the alarm and close the ammonia gas supply line.

Mosty in North India (UP, Bihar, MP, Rajasthan , Delhi NCR, Punjab, Mumbai Etc.) we come across the news of leakage of Ammonia gas (Ammonia Gas Rishav) from the cold , Fruit Ripening Chamber and Ammonia factories  and this causes the Death of number of innocent people working in the primieces and also who lived near to the spot of incident due to inhaling of ammonia gas present in air due to this leakage .

Recently in 2018 till now 3-4 cases of Ammonia Gas leakage took placed  in  Kanpur, Allahabad and Punjab where numbers of people suffered and died along with numbers of Animal and Birds .

To stop all these types of panic incident by using MSR Germany  Ammonia Leakage Detector Transmitter in such places to ensure the safety of life of your worker and nearer .

We at www.alviautomation.com working in the field of Gas Leak Detection System and our Motto is save the Environment for all, for this we are committed to serve you all through our experience, supply, support & consultancy .

For any query and enquiry please feel free to contact us – Info@alviautomation.com.

 

Carbon Monoxide (CO) Detector – Best German Technology

We are pleased introduce  Carbon Monoxide (CO) Detector – Best German Technology  in most economical cost compare to the  market price of other competitor brand .

As we all know that Carbon Monoxide  gas is also called silent – invisible killer as CO doesn’t have smell, colour  or tase .

Any time you burn something—like gasoline, natural gas, wood, oil, propane, or charcoal—carbon monoxide is released into the air. In outdoor spaces, this usually isn’t a health hazard because there is enough area for the CO to dissipate, so particles never amount to a toxic level. The danger comes when carbon monoxide is released in a contained area like your home, RV, or garage, Car Park, Coal Mines, Industries.

It is most important for everyone to install CO detector in their premises as mentioned above it is best security system of their life and property as CO detector can also intimate you if there is any fire in the premises .

For any enquiry or query please feel free to contact us  in  our mail id – info@alviautomation.com

Environmental Safety – Gas Leakage Monitoring & Control Systems

Everyday we come across a news of hazardous incident of fire in hotel, resident, industries, etc, the tragedy happen due to the leakage of combustible/explosive gases or sudden electrical spark and the carelessness of management systems.

On 31st May we came  across a news that Gas leakage causes fire in Jindal factory in Narol area in the evening on Wednesday 30th May the incident took place at the godown of the factory which had storage of Hydro, indigo, caustic soda, pigments and starch. Earlier, in four different incidents, there were reports of gas leakages.

We all know that in market there is lots of gas leak detection and early fire detection system which stop the horrible incident by intimating the managements by actuating  Alarm , Closing  gas Supply System , sending Messages to the concern  team & many more options .

We request you to put your concern towards the Gas leakage,  life, property and Environmental issues and stop these kind of painful incident in our country .

We at www.alviautomation.com promise you to provide you best German Technology for the safety of your  premises.

We feel pleased if we can assist you, guide you and provide you our best consultancy and product services.

Gas_Detecton_System #Stop_fire_Incident #Stop_Hazardous_Tragedy #Save_Life #Save_Energy #Save_Environment & #save_money ..!

CO Sensor Transmitter – CO Gas Effect on Health

Carbon Monoxide gas is colourless, odourless and tasteless gas that is slightly less dense than the air . It is toxic to hemoglobic animals when encountered  in the concentration above 35 ppm .

CO Gas produce due to partial oxidation of carbon containing compounds; it forms when there is not enough oxygen to form CO2 .

It may produce due to burning of wood (Smoke), from bike, auto, and any vehicle  etc.

It affect human body as per the level of gases in surroundings / environment as defined  in below table –

Effect of CO in Health

People need to be aware of CO gas leakage/ presence in the primicess cause some time it is more hazardous than we imagine .

We at www.alviautomation.com  committed to provide you complete solution of CO Gas Detector and Control Monitoring Systems .

For any query and gas leak detector please feel free to contact us .

 

Put your concern towards the gas leak incident in plant and industries

#Gas_Detecton_System #Stop_fire_Incident #Stop_Hazardous_Tragedy #Save_Life #Save_Energy #Save_Environment & #save_money ..!

Everyday we come across a news of hazardous incident of fire in plant,  hotel, resident, industries, etc, the tragedy happen due to the leakage of combustible/explosive gases or sudden electrical spark and the carelessness of the management and security systems.

we all know that in market there is lots of gas leak detection and early fire detection system and gas leak detection systems which stop the horrible incident by intimating the managements by actuating  Alarm, locking gas Supply System or can say close the solenoid valve , messages & many more options are there .

But sadly saying that in India 60%people who needs fire and gas leakage monitoring and control system in their premises are not using these system in their premises .

We request you to put your concern towards the security system, Life and Environmental issues and stop these kind of painful incident in our country.

For all types of gas detector process instruments  energy saving & field instruments you can contact us

We feel pleased if we can assist you, guide you and provide you our best consultancy and product services.

We at Alvi Automation promise you to provide you best German Technology to save your Life, Money, Plant, Industries, Building etc. ..

Carbon Monoxide (CO) Detector For Car Park Ventilation Systems

When it comes to Carbon Monoxide Detection in Car Park Ventilation Systems, Our  European Standard  MSR CO Sensor Transmitter have great demands in global market.

Now available with special  promotional discounted price for Indian market with following details :

Ideal for :
Parking area, garages, chiller rooms and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points :- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smouldering fire and smoke detection.
  • VEFSA system (very early fire and smoke alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in Stock : – MA-0-1110-F-B
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three wire sensor
  • Response time T90:-  ≤ 50 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in : IP44/54/65/66 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 5 years (Site Feedback ≥ 10 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 750m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature :–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal :- Standard: 4-20 mA Linear Output, also available in 2-10VDC
  • Flammability: – UL 94: V0
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval : EMC Directives 2004/108/EC, CE.

For Technical Datasheet please click here 

Natural Refrigerant Gas Leak Detection

We are pleased to introduced Natural Refrigerant Gas Leak Detection & Control Alarm System in Australasian Countries.

MSR Germany PolyGard2 Natural Refrigerant Gas Leak  Detector and Control Alarm System (CO2, Hydro-carbons including Ammonia, HCF, HCFC) is designed to continuously monitor for Leaking Refrigerants in the trace levels.

Features:

  • Monitor CO2 Refrigerant leaks in 0-2000 PPM range
  • Monitor hydro-carbon leaks in 0-100 % LEL (methane, LPG, propane, butane etc)
  • Duct mount option for detection of leaking refrigerants in return ventilation ducts
  • Integral relay option (DPDT, 5 A, 250V contacts) for A-V Alarm or ventilation fans or shutting off gas supply solenoid valves
  • Stand-Alone, wall mount Refrigerant Leak alarm, 24 V AC/DC operation, with display, 4 x Relays for fans,  A-V Alarm, diagnostics/watchdog with system fault relay, analogue output for PLC, BMS, SCAD
  •  Multi-point Monitoring System with 4 – 24 Remote Transmitters for CO2, Ammonia, Hydro-carbons
  • Option of Remote sensor/transmitters in IP 54, IP 65, Stainless Steel housings
  • Infra-Red based, gold-plated CO2 sensor with Automatic Background Calibration (no maintenance required)
  • Hand-held portable CO2, Ammonia, hydrocarbon detection instruments
  • Oxygen Monitoring Transmitters for 0-25 % Vol O2 (oxygen deficient atmospheres created by CH4, CO2
    in enclosed areas.

For more details and query please   Click Here  

Lithium- Ion Battery Fires – Hydrogen Fluoride Detector

Gas Safety Risks: Lithium- Ion Battery Fires – HF (Hydrogen Fluoride Monitoring Systems)

Li-Ion batteries are now widely  used in mobile phones, electric vehicles, laptops including MW range of Renewable Energy Storage plants, aircrafts, submarines, mine-shafts and spacecrafts.

Gas Safety risks  in Li-Ion battery charging rooms:

  • Li-Ion batteries when overcharged or short circuited are overheated and catch fires
  • Li-Ion battery fires have caused great concern because of risks due to spontaneous fires and intense heat generated by such fires
  • As a result of the above-said a lethal amount of toxic Hydrogen Fluoride Gas, HF is generated.
  • HF from Li-Ion battery fires can pose severe gas safety risks in confined spaces like battery charging rooms, renewable energy storage plants in solar or wind power plants
  • The electrolyte in Li-Ion battery is flammable and generally contains Lithium Hexa- fluoro -phosphate (LiPF6)
  • In the event of overheating due to overcharging or short circuiting  and backed by high temperature, the electrolyte in Li-Ion batteries will vaporise liberating toxic gases like CO, CO2, HF (hydrogen fluoride)
  • The moisture and humidity will further exacerbate the situation generating more HF (reaction of LiPF6 with water or humidity)
  • Typical HF concentration expected can be as high as 20-200 ppm of HF (NIOSH/USA Safety limit , TWA:3 ppm HF, STEL: 6 ppm HF)

Solutions:

  • Continuous monitoring of HF, Hydrogen Fluoride in toxic range of NIOSH/USA : 0-10 ppm
  • Continuous monitoring of other toxic gases like CO, CO2 (gases generated due to  combustion fires)
  • Continues monitoring of humidity and temperature
  • VEFSA (Very early fire and smoke alarm)

Typical Systems:

  • Single Point stand alone gas controller for HF, CO, CO2, Temperature, Humidity
  • 1-4 channel HF, CO, CO2 Sensor/Transmitters with 4 channel Gas / PLC controller
  • Warning alarm to plant people including GSM Alarm dialler capability to mobile phones
  • DIGITAL MULTI-CHANNEL system for Renewable Energy Storage Plants for HF, CO, CO2, Temperature, Humidity
  • Save 60-80 % costs on cable, cabling, installation with our DIGITAL SYSTEM

VEFSA: Very Early Fire and Smoke Alarm: For very early fire detection in electrical cabinets, switchgear rooms. Our sensing system is designed to pick up enhanced gas radicals which are liberated during overheating of PCBs, electrical insulation breakdown due to short circuit or earth fault, transformer insulation breakdown, again due to short circuit or earth fault. Please note  by the time the conventional fire detection system like VESDA or conventional smoke sensors  pick up the smoke, it is already too late. Our VEFSA Gas Radical Sensing System can detect the gas radicals and shut off the mains/power supply thus protecting millions of dollars of assets

Continue reading “Lithium- Ion Battery Fires – Hydrogen Fluoride Detector”

Battery Room Application – Hydrogen Detector

Hydrogen detector for battery room application.

Advance German technology with high accuracy and long life, easy maintenance and low price cost .

Technical Specifications:

  • Measuring Parameters: Hydrogen gas flammability or leakage
  • Sensor Technology: Catalytic bead based pellistor sensor cell
  • Measuring range: 0 ~ 100 % LEL
  • Response time (t90): < 10 sec
  • Control unit: 12 bit microprocessor based
  • Warm up time: < 5 mins
  • Auto zero point tracking for drift compensation
  • Power supply: 24 VDC
  • Ingress protection:  IP 54, IP 65, IP 66, IP 68
  • Enclosure: Polycarbonate material, also available in Stainless steel (for sensor cell), Cast Aluminium (for transmitter).
  • Output: linear, proportional 4-20mA or 2-10Vdc
  • Mounting: wall, duct, pipeline
  • Safety integrity level: SIL 2
  • Optional: LCD Display, alarm LEDs, potential free relay contacts
  • Also Available for Hazardous area: Zone 1, 2

Application:

  • Battery rooms, UPS facility
  • Oil & Gas, Petrochemical, refinery
  • Mobile switching center (MSC) of cellular / telecom site
  • Cracking plants
  • Hydrogenation plants
  • Chemicals
  • Cold stores
  • Pharmaceuticals, medicinal formulation

For more details please feel free to contact us

For Technical Datasheet Please Click Here 

Carbon Monoxide (CO) Detector – Parking Systems

Carbon Monoxide Detector Transmitter is used to provide a proportional analog signal to the Multi-Input Control Panel or a Building Management System (BMS)                 

Ideal for :
Parking area, garages, chiller rooms and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points :- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smouldering fire and smoke detection.
  • VEFSA system (very early fire and smoke alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in Stock : – MA-0-1110-F-B
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three wire sensor
  • Response time T90:-  ≤ 50 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in : IP44/54/65/66 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 5 years (Site Feedback ≥ 10 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 750m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature :–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal :- Standard: 4-20 mA Linear Output, also availabel in 2-10VDC
  • Flammability: – UL 94: V0
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval : EMC Directives 2004/108/EC, CE.

For Technical Datasheet please click here 

Best CO (Carbon Monoxide) Detector & Alarms

Low Pricing, Best Technology, High Accuracy, Long Life, Carbon Monoxide Gas Detector and Transmitter .

Benefits of CO Monitoring:
The very early sign in coal handling/processing plant fire is liberation of gas radicals (CO predominant). The idea is to detect the presence of this CO gas radical for very early fire prevention. By the time smoke is generated and detected it is already too late. A typical CO monitoring system for detection of products of combustion fires or spontaneous combustion of coal fires can warn potential fire two days in advance then flame is present or detected. By installing an effective CO and CH4 monitoring system, coal based power stations can benefit in the following ways:

  • Reduced insurance premiums
  • Better safety to plant and personals
  • Reduced down time
  • Prevention of loss of resources
  • Save time and money.

Why CO monitoring? :
Coal contains moisture which when liberated, coal gets oxidised, generating both heat and carbon monoxide. This heat when builds-up has the potential of creating spontaneous combustion of coal fires.
Coal is extremely friable and can be easily crumbled or pulverised. Further coal also generates coal dust needing extra preventive measures like proper maintenance of stockpiles, guarding against accumulations of coal in the fuel-handling system, compaction of stockpiles, cleaning spills and washing float dust. The most effective programme for fire-prevention would be to have Carbon Monoxide Monitoring and Control System
CO Monitoring Installation Aspects:
There will always be some safe background CO levels in coal handling or processing plants under normal operating conditions. These CO levels will rise during coal loading, handling and will again settle to normal levels once loading is finished and ventilation fans are running. It is important to find out the normal background CO levels by installing CO data-loggers and observing the CO generation trends under normal operating conditions of the plant. A typical CO level of 50 ppm of CO is normally present in background levels when coal is being handled, moved or transported. Based on these normal background CO levels the sizing/selection of the CO system (range etc) and alarm set points need to be undertaken.

Location of Sensors:
In general, it is wise practice to locate an adequate number of sensors at strategic locations based on knowledge of the potentials for ignition. When considering belt fires, sensors should be located in close proximity to drives, tail pieces, and main rollers.
When coal is the issue, any location where accumulation of coal dust or bulk quantities is likely or expected should be considered. These include belt transfers, crushers, dust collection systems, and storage bins (silos, bunkers, etc.).
System Approach:
A typical system may consist of number of CO (range: 0-300, 500 or upto 1000 ppm) and or CH4 (range: 0-100% LEL) gas sensor/transmitters installed remotely at strategic potentially risky areas. The 4-20 mA output coming from these sensor/transmitters can be connected to a multi-channel gas controller which can handle from 2 to upto 96 remote sensor/transmitters. When CO concentration levels rise beyond the set limit (say above 100 ppm, depending on safe background levels), the built in relay contacts will automatically generate audio-visual alarm for plant supervisor to take corrective measure (ventilation fans, mains shut-off etc).

Fore more details Please read our article on CO Monitoring By Mr. Alak Jha  : Articles-COearlyFire-CoalPowerPlants

ATEX – Approved Online Sensor Transmitter

Description: 

  • Toxic and Combustible (CO, CO2, natural gas, Methane, LNG, PNG) sensor transmitter for online, continuous LEL / flammability or leakage detection in ambient air or ducts.
  • The detector is explosion proof IECEX, ATEX certified with SIL 2 safety level and suitable for installation in hazardous area Zone 1 and Zone 2.
  • The instrument can be installed at landfill application, sewage treatment plants, fertilizer industry, gas bank etc.
  • It is available with LCD Display, onboard relay contacts, flashing alarm LEDs, auto diagnostic watchdog, non-intrusive calibration, with the industry standard linear analog output.
 Combustible  gas sensor – online LEL monitor with ATEX, IECEX, SIL 2

Methane, chemically known as CH4 is highly flammable, lightweight gas with LEL at STP 5% v/v.

Methane gas detector series is highly robust, industrial grade, flameproof or explosion proof gas detector for methane leakage detection or LEL monitoring. Methane is also available in form as natural gas, pressurised natural gas (PNG), liquefied natural gas (LNG).

The detector is used for online, continuous monitoring of the flammable concentration of methane in PPM, %LEL or %Vol terms in ambient air or in duct or pipeline. It is ATEX, IECEX certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

The sensor transmitter offers linear, proportional analog output in industry standard current signals, over measuring range of 0-1000, 0-2000 PPM,     0 ~ 100 % LEL (lower explosive limit). The detector works on highly sensitive catalytic bead-based pellistor sensor cell, with low response time. It has unique feature of auto diagnostic watch dog with zero point tracking feature. Due to its 12-bit microprocessor based control unit, it offer high accuracy over long term. The detector is also equipped with sintered filter with flashback arrestor for enhanced safety.

It also offers optional features like inbuilt LCD display, flashing alarm LEDs, onboard potential free relay contacts (24VDC @ 1 A), RS485 serial interface with Modbus RTU communication.

Key Features:

  • Catalytic bead based Pellistor, Electrochemical sensor cell with low flash energy
  • 12-bit microprocessor control unit
  • Non-intrusive one man calibration via hall effect switches
  • ATEX certified explosion proof / flameproof, suitable for Zone 1, 2 gas explosion installation
  • Linear, proportional analog industry standard current output
  • Continuous system self-diagnosis with watch dog
  • Flashback arrestor with sintered filter
  • Auto Zero point tracking to zero point compensation
  • SIL 2 HW TUV certified
  • RS485 serial interface with Modbus RTU communication (optional)
  • 1 or 3 relay output module (optional)
  • System and alarm LED indicators (optional)
  • Modbus RTU communication over RS485 serial interface

MSR PX2 for Combustible_Flammable Gas

Continue reading “ATEX – Approved Online Sensor Transmitter”

Online Ammonia Gas Leakage Detection

ALVI Automation in association with ALVI – Technologies feel pleased to offer Ammonia Gas Leak Sensor Transmitter in Indian and Australasian countries to stop and control the hazardous tragedy caused by leakage of Ammonia gas from the food industries like cold storage, fruit ripening chamber and also from the chemical and gas factories .

Sensor offered by ALVI Group are having all advanced and new German technologies, as all these sensor are manufactured in Germany hence the quality and reliability are assured.

Ammonia (NH3) Gas Leak Sensor Transmitter Description are as follows : 

Model no :MC2-D-E1125-C-X

Make : MSR German

  • Measuring Range : 0-300/500/1000 PPM
  • Gas Type : NH3
  • Sensor Cell : Electrochemical
  • Operating Voltage : 24 VDC
  • Output Signal : 4-20 mA or 2-10 VDC
  • Housed in IP65 polycarbonate enclosure
  • Housing UL94 V2 approved
  • Wall mount housing
  • Calibration interval : 12 month
  • Continuous Monitoring
  • High accuracy, selectivity and reliability
  • Low zero point drift
  • Long life sensor
  • Easy maintenance and calibration by exchange of the sensor unit or by comfortable on site calibration
  • Software according to SIL2 compliant development process

For more details and quote please mail us on : Info@alviautomation.com