Carbon Dioxide Transmitter, Monitor and Controller

CO2

Carbon dioxide (CO2) is the second main gas responsible of the greenhouse effect and the major gas discussed during environmental summits. It is mainly used, according to its state:

  • Under its solid state, carbon dioxide (CO2) is used as a cool pack.
  • Under its gaseous state, it is used in the beer brewing and the wine growing
  • Under its liquid state, carbonic gas is used to charge efficient extinguishers against any type of fire.

It is the result of complete combustions, both natural (volcanic eruptions, fire, etc.) and anthropogenic (car engine combustion, industry combustions, etc.)

Naturally present in the atmosphere at low concentration, carbon dioxide (CO2), also known as carbonic gas, remains hazardous. As it is essential for photosynthesis, it can be found in greenhouses to increase plant growth.

EFFECTS OF CARBON DIOXIDE ON HEALTH

CO2 effect

FEATURES OF CARBON DIOXIDE

The carbonic gas is colourless in the visible light but absorbing in the infrared spectrum, and such is responsible of the greenhouse effect.

Odourless, non-flammable and non-toxic, carbon dioxide (CO2) is produced in the body and eliminated in the lungs.

Nevertheless, the carbonic gas features asphyxiating properties. As it is heavier than the air it is present in the poor ventilated locations (confined spaces) like tanks, sewers, holes…

GasAlarm CO2 GAS DETECTOR

CO2 gasalarm

Fixed gas detection systems are able to measure the carbon dioxide variations.

  • GasAlarm CO2 gas detector like the GAS-CO2-XXX allows percentage by volume measurements of the carbonic gas variations in the atmosphere.
  • To monitor an area where several people work together like maintenance works in confined spaces.
  • The fixed GasAlarm CO2 gas detection systems come with the following features:
  • Measuring range: 0-5000 PPM or 0-2000 PPM
  • Relay output: One passive relay output (max.5A)with the control mode selection with an inbuilt buzzer
  • OLED Display
  • Modbus RS485 output for BMS integration
  • Color changeable LED light
  • Supply voltage: 24VAC/VDC

click here to download the datasheet

For more information please feel free to contact us or mail us at info@alviautomation.com

 

 

Carbon Monoxide Sensor Transmitter

We  ALVI Automation India Private Limited in association with  GasAlarm Systems  company based in Sydney, Australia (www.gasalarm.com.au) specialising in gas detection & monitoring solutions feel pleased to introduce our new and and best reliable Carbon Monoxide Sensor Transmitter  GAS-CO-300-X

Introducing the GasAlarm Systems GAS-CO-300-X

Most cost optimum sensor transmitter  for carbon monoxide – application in car park ventilation fan control, coal mining , coal handling plant, coal washeries , boilers , steel plants, pharmaceutical anywhere gas and coal combustion takes place – best very early fire detection due to gas radicals detection – smouldering fires.

 

Specifications in Detail:

  • 24VDC power with 4-20mA output (current loop)
  • 0-300PPM Carbon Monoxide measuring range
  • Long Life – ≥ 6 years (Life Expected  ≥  10 years)
  • High Accuracy –  ± 3ppm
  • Wiring – 2 wire system (reduce wire cost)
  • Onboard potentiometer for “zero” adjustment
  • Onboard potentiometer for “gain/span” adjustment
  • Multimeter connections for measurement during calibration
  • With “D” enclosure option, rated at IP65
  • With “F” enclosure option, rated at IP44
  • Calibration Interval – 12 Months
  • Easy to use with low maintenance  cost .

Click here to download the datasheet

For more query and enquiry please contact us : Info@alviautomation.com 

The PERFECT Low Cost CO Detector for the EMERGING Countries

We GasAlarm Systems in association with ALVI Automation India Private Limited, is a company based in Sydney, Australia (www.gasalarm.com.au) specialising in gas detection & monitoring solutions.

With over 40 years of experience in the industry we like to think we know a little about the industry and how its changed over the decades.

What we found lacking was good quality reliable products which were low cost, especially for the developing/emerging markets & countries.
So, we’ve taken it upon ourselves to slowly introduce such products one by one.

We dedicated to start with the most common product in gas detection worldwide, the humble CO sensor.
Countless brands, models & technologies exist however we feel ours has hit the spot when it comes to the all-important price and performance ratio.

We’ve kept it extremely compact!
We’ve kept it extremely simple!

We’ll be honest, our aim is to sell this product at extremely low margins however in large quantities.
Thus, ensuring you, the customer keeps buying and sees the value add in the product locally.

Introducing the GasAlarm Systems GAS-CO-300-X

The all-in-one sensor/transmitter is made in Germany under an OEM exclusive agreement for us.
It uses an electrochemical sensor cell. NOT semi-conductor or MEMs semi-conductor like other cheap products!
It offers an industry standard measuring range of 0-300 ppm.
It runs on an industry standard 2 wire 24VDC current loop with a 4-20mA output.
It has 2x onboard potentiometers for future on-going calibrations, A zero & a span/gain pot.

To save you costs on freight & to help you with your own branding, we would be happy to sell these without an enclosure/housing.
You can then mount them locally in your own enclosure with your branding & part number!

In a small tray measuring 28cm (11in) x 19cm (7.5in) x 4cm (1.6in) we can fit 10x units without enclosures! We would add extra padding & another carton before shipping. Of course, if needed we can supply these with an enclosure as well.

Specifications in Detail:

  • 24VDC power with 4-20mA output (current loop)
  • 0-300PPM Carbon Monoxide measuring range
  • Long Life – ≥ 6 years (Life Expected  ≥  10 years)
  • High Accuracy –  ± 3ppm
  • Wiring – 2 wire system (reduce wire cost)
  • Onboard potentiometer for “zero” adjustment
  • Onboard potentiometer for “gain/span” adjustment
  • Multimeter connections for measurement during calibration
  • With “D” enclosure option, rated at IP65
  • With “F” enclosure option, rated at IP44
  • Calibration Interval – 12 Months
  • Easy to use with low maintenance  cost .

For more query and enquiry please contact us : Info@alviautomation.com 

GAS ALARM SYSTEM with Control and Monitoring Solution for Glass Plant Application

industry

ALVI Automation/Gas Alarm Systems designed engineered PLC & HMI based gas detection, monitoring  and control solution which include:

The Gas Alarm system components shall have similar features as specified below:
1. Gas controller cum display unit:
It shall be digital programmable logic controller (PLC) with CPU based, based on decentralized monitoring architecture with: 5 x slave controller (without display, with local digital output for alarm / Fan / Valve control etc) modules over RS485 serial interface TCP/IP or ModBus Communication, 1x Master Controller (with 10 inch colored touch-screen HMI LCD Display, with digital output for alarm / fan / valve control)
Display would show: gas concentration at each sensor, sensor status, sensor location, alarm status, system error, fault location etc Integrate able with BMS/ SCADA, Fire alarm system Configurable alarm threshold via touchscreen display password protected Simple English menu for configuration, with aux. power supply to sensor transmitters, wall mountable IP65 metallic / ABS fire retardant enclosure (non explosion proof), fire retardant panel wiring, 230VAC 1-phase power supply, with bench-top programming.

IMG_20161125_161442825panel 1

2. Hydrogen gas sensor/detector transmitter:
It shall be online, continuous monitoring of hydrogen in ambient air, measuring range: 0-2000 ppm H2, Electro-chemical sensor cell technology, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, SS 316 sensor cell enclosure with flash back arrestor and sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection. CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved EMC EN50270, EN 61000, ATEX, IECEX compliant

MSR PX2 Series Sensor Transmiter
3. Oxygen gas sensor/detector transmitter:
It shall be online, continuous monitoring of oxygen gas in ambient air, measuring range: 0-25% v/v O2, Electro-chemical sensor cell technology, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, SS 316 sensor cell enclosure with flash back arrestor and sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved EMC EN50270, EN 61000, ATEX, IECEX compliant

H2 ARB2 sesnor
4. C2H2 (Acetylene) gas sensor / detector transmitter:
It shall be online, continuous monitoring of acetylene in ambient air (in chloride containing background gases), measuring range: 0-100% LEL C2H2, reliable infra-red sensor cell with poisoing and etching immunity, self-compensating optics, pressure and temperature measurement, isolated RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated aluminum enclosure, SS 316 sensor cell enclosure, with back-lit LCD display, 24V DC powered, response time < 10 sec, IP65 ingress protection CSA/NRTL Class, Div 1, ATEX, IECEX, Group A,B,C,D T5 IECEx Ex d IIB + H2 T5 Gb, for Zone 1, 2

hydrogen-sensor-500x500
5. Silicon Chloride (SiCL4) (HCL) gas sensor/detector transmitter:
It shall be online, continuous monitoring of Silicon Chloride in ambient air (in chloride containing background gases), measuring range: 0-20 ppm SiCl4, reliable electro-chemical (galvanic) sensor cell with poisoing and etching immunity, self-compensating optics, pressure and temperature measurement, isolated RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated aluminum enclosure, SS 316 sensor cell enclosure, with back-lit LCD display, 24V DC powered, response time < 15 sec, IP65 ingress protection AYEX, IECEX, SIL2,  CSA/NRTL Class, Div 1, Group A,B,C,D T5
IECEx Ex d IIB + H2 T5 Gb, for Zone 1, 2

MSR_PolyXeta_mit_Display_RAL_7035_Alarm
6. GeCL4 gas sensor / detector transmitter:
It shall be online, continuous monitoring of GeCl4 gas in ambient air (in chloride containing background gases), measuring range: 0-20 ppm GeCl4 (calibrated against HCl), Electrochemical sensor cell technology, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, corrosion resistant SS 316 sensor cell enclosure with flash back arrestor and sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved, ATEX, IECEX, SIL2,  EMC EN50270, EN 61000 complian

ADT MC2 sensor

7. CL2 gas sensor/detector transmitter:
It shall be online, continuous monitoring of Cl2 gas in ambient air, measuring range: 0-20 ppm Cl2, Electro-chemical sensor cell technology, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, corrosion resistant SS 316 sensor cell enclosure with flash back arrestor and sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved, ATEX, IECEX, SIL2 EMC EN50270, EN 61000 compliant

CO Sensor Transmitter
8. CH4 (Methane) gas sensor / detector transmitter:
It shall be online, continuous monitoring of CH4 gas in ambient air (in chloride containing background gases), measuring range: 0-100% LEL ppm CH4, reliable infra-red sensor with poisoning and etching protection, RS485 serial interface with MobBus RTU communication, 4-20mA analog output linear proportional, anti-static epoxy coated metallic enclosure, corrosion resistant SS 316 sensor cell enclosure with sintered filter, without on-board display & relays, 24V DC powered, response time < 15 sec, IP55 ingress protection CESI 03 ATEX 339, ATEX II 3G EEx nAd nC d IIC T6 for Zone 2 explosion proof area; CESI 02 ATEX 084 performance certified SIL 2 HW approved, ATEX, IECEX,  EMC EN50270, EN 61000 compliant

For more details please contact us or drop a mail to info@alviautomation.com we would be happy to serve you:)

GmbH German Sensor Technology

MSR Germany Gas Detector technology stands for qualitatively high-grade and innovative products and solutions in the field of Gas leak Sensors and controller. Our goods and services are concentrated on the needs of our customers, who can rely on the fulfillment of their requested service. Adherence to schedules and an outstanding quality are at the core of our consequential customer orientation.

The constant quality optimization of our products and processes, as well as the consequential enhancement of operational quality management systems, is as a matter of course for us.

Within the framework of our quality management system, continuous improvement processes are being consequently developed further that have the effect of increasing quality.

An environmental management system in accordance with ISO 14001 is implemented and will be continuously developed further.

A quality management system in accordance with ISO TS16949 is in the final implementation stage.

An essential factor of success is our highly qualified and motivated employees. We choose our employees according to our range of services, the demands of our clients, and our company’s philosophy. We attach a great importance to the constant further qualification of our personnel.

Come join our hands and make our planet a better place to live

For more details please click here

LPG Detector – Liquified Petroleum Gas Leak Detection Systems

GasAlarm India pleased to offer LPG sensor transmitter / detector/ analyser in association with ALVI Technologies- Australia &  MSR Germany with following features:

  • Measuring range: 0-100% LEL (lower explosive limit), 0-100% Vol (analysis)
  • Technology: Pellistor / catalytic bead (flammability monitoring), Infra-red
  • Output: 4-20mA, 0-10V, RS485 modbus, Lon, BacNET
  • Enclosure: IP44, IP54, IP65
  • Certificate: UL 61010, UL 2075, ATEX EExd, ATEX EExn, CE
  • Mounting: wall mountable, duct mountable
  • Installation area: safe area, hazardous area, explosion-proof

Application areas: Kitchen , gas bank, bottling plant, booster station, gas store, pharmaceutical, cylinder store, gems processing, heat processing, furnace, engine room, testing rooms, automobile, defence, warship, annealing plant, chemical plants, oil & gas, fire safety, domestic gas pipeline, kitchen, refinery, food processing, cement, bearing, machine industry, swimming pool, combustion area, bakery, commercial, hotels, mines, confined space, gasifier, stockyard, oil wells, biogas plant, landfill, boiler plant, thermal power plants etc
Features:

  • reverse polarity protected
  • poisoning protected
  • low flashing temperature for longer sensor
  • modular architecture
  • manual calibration
  • expected life: 3 years-15 years
  • low response time
  •  Conformity to
    o EN 50271
    o EN 61010-1
    o ANSI/UL 61010 1
    o CAN/CSA-C22.2 No. 61010-1

Gas type available: combustible gas detector, confined space gas detector, gas detection system, gas detectors, gas analyzers, exhaust gas analysers, biogas analyzers, stack gas analyser, catalytic gas sensor, combustible gas sensor, gas sensors, hydrogen gas sensor, methane detector, LPG bottling plants, LPG burners, LPG cylinder plant, LPG fuel tank, lpg gas leakage sensor, gas train, lpg gas tanker, lpg station, lpg vaporizer, natural gas alarm, natural gas plants, combustion analyzer, biogas generation plant, biogas generator, biogas power generation plant, biomass gasifier, propane vaporizers.

 

Flame Detector : With Analog Output

Gas Alarm India in association with  Gas Alarm – Australia takes pride to introduce flame detector in India.

Detector / transmitters / ANALYZER / MONITORING for explosion proof hazardous area (zone 1, 2)

Explosion proof ATEX logo
Detector / transmitters / ANALYZER / MONITORING for explosion proof hazardous area (zone 1, 2)

Detector or sensor transmitter for online, continuous monitoring of all type of flame/fire. These transmitters offer German industry standard analog output in current or voltage form, or digital signals like Modbus RTU with RS485 serial interface. Optionally, these are also equipped with potential free relays.

These can be mounted on wall, ceiling, columns, ducts or pipelines. These can be single gas or multi-gas detection transmitters.

The sensor instruments are SIL 2 certified to offer best safety.

For More Details : Please click here

Importance of CO2 Measurment Inside Metting Rooms, Classrooms, Offices etc

CO2 has been a hot topic for a number of years mainly in relation to climate change and government policy. Leaving all of that aside, monitoring and controlling indoor levels of CO2 is important for everyone to consider for health, safety and even energy efficiency.

CO2 is a known indoor pollutant affecting performance in the workplace, at school, and even at the gym. Extreme levels of CO2 can lead to death, particularly in enclosed spaces such as laboratories, some hospital rooms, and breweries. CO2 can have a number of effects on home and workplace health and safety.

Controlling CO2 can also improve building energy efficiency, saving costs by up to 80%, and is even considered in the scoring of Green Star Ratings in building design.

Here, we outline reasons why you should be measuring carbon dioxide levels inside buildings.

1.      CO2 can kill you
Outside air has a CO2 concentration around 400ppm and each human breath contains around 30,000ppm. CO2 concentrations greater than 20,000ppm cause panting; above 100,000ppm (10%) CO2 can cause tremors and loss of consciousness; and values above 250,000ppm (25%) can lead to death. CO2 can be hazardous in one of two ways: by displacing oxygen in the blood or acting as a toxin.

2.      CO2 can decrease productivity
In the office and classroom, elevated levels of CO2, in the range between 1,000ppm and 2,500ppm, have been found to decrease information utilisation, increase headaches, decrease performance, and increase rates of absenteeism. Generally, CO2 concentrations at 1,000ppm can lead to a statistically significant decrement in decision making performance. CO2 concentrations at 2,500ppm, on the other hand, lead to large and highly significant decrements in decision making performance.

Although CO2 is not the only factor, elevated levels can lead to that feeling of lethargy and tiredness often associated with office workers. Studies have shown that performance, associated with lethargy induced by elevated CO2, can decrease by up to 10% for adults and over 20% for schoolchildren.

CO2

3.      CO2 can increase rapidly in poorly ventilated rooms
Figure 1 shows how rapidly levels of CO2 can increase in a poorly ventilated office. For example, in a 3.5-by-4-metre sized office with a single occupant, CO2 increased from 500 ppm to over 1,000 ppm within 45 minutes of ventilation cessation.

 

Edaphic Scientific CO2 Levels for HVAC and IAQ

Figure 1. An example of increasing CO2 concentration in a poorly ventilated office with a single occupant.

 Generally, where large numbers of people gather then CO2 will increase rapidly and lead to poor indoor air quality and pollution. In offices, this could be meeting rooms where a number of staff gather for extended periods in confined spaces.

Other places, such as gyms, shopping centres, cafes with soft drink vending machines, or libraries, are increasingly being recognised as indoor environments with elevated CO2 leading to poorer performance.

4.      Some locations have naturally high CO2 levels and need to be monitored
There are certain locations where indoor CO2 in an enclosed room or area can potentially reach extreme and life threatening levels.

Any enclosed or poorly ventilated location where CO2 cylinders are stored or used will potentially have harmful levels of atmospheric CO2. Examples of such locations include laboratories and hospitals.

Other spaces where CO2 is regularly used in the manufacturing or work process are also potential areas of harmful levels of CO2. Breweries are potentially extremely hazardous. Pockets of high CO2 can form in tanks and cellars and can quickly lead to death. Even bars, clubs and pubs, where CO2 cylinders are stored in a room, are increasingly required to monitor CO2 levels for workplace safety.

Using CO2 sensors for ventilation control can assist in these cases. However, other systems with audible and visual alarms, such as the  can be installed (Figure 2) warning workers and occupants of dangerous levels of CO2. The sensor is installed in the space with the CO2 source and an alarm indicator is placed outside.

5.      The novelty factor
Measure indoor levels of CO2 is new to most people. In fact, most people would not have a clue what the CO2 levels in their room are, what they should be, and how they change throughout the day with various factors.

Monitoring CO2 levels with a data logger is interesting, or having a wall-mounted or desktop LCD read-out, showing real-time CO2 levels, is also interesting. Informing your guests that you are controlling the ventilation in your building with a CO2 detector will certainly raise a few eyebrows!

CO2 2

In conclusion, a work or learning place designed for optimal productivity leads to better performance and, ultimately, is better for the bottom line. Monitoring and controlling CO2 levels is one approach to a healthier workplace environment by using cutting edge MSR Germany CO2 sensor range detectors.

For More Details and to avail special offers please contact us

Monitoring CO2 in Breweries

CO2 is extremely hazardous as it is completely odourless and colourless and there is no physical indication of danger until it is usually too late.CO2 is a hazard throughout the brewing process, right through to packaging and bottling because as it is heavier than air, it collects at the bottom of containers and confined spaces such as tanks and cellars and can even spill out of fermenting tanks and sink to the brewery floor, where it forms deadly, invisible pockets. To avoid the hazards associated with CO2, Monitoring CO2 in Breweries is quite essential.

The majority of Carbon Dioxide gas in beverage industry is used during carbonating process. It is also used in fermentation and refrigeration.

During the bottling process a high volume of Carbon Dioxide can be emitted into the plant room. Also during transport or storage of Carbon Dioxide, there is always a risk of unnoticed gas leakage. Exposure to elevated levels of CO2 can cause headaches, drowsiness or even sudden death. Hence facilities where there is a possibility of Carbon Dioxide reaching to the dangerous level, an accurate and reliable CO2 control system should be installed to maintain a healthy work-place.

Carbon Dioxide is also released during fermentation process. To achieve and maintain high operational safety the level of CO2 should be controlled in fermentation rooms by continuously monitoring CO2 Breweries fermentation rooms.

At ALVI we offer innovative sensors and controllers to identify and immediately display the life threatening CO2 gas. These products are based on years of experience and were compiled with a lot of know-how and tailored to individual customer application.

Please click on the link below for products we can offer for CO2; backed with our support and expertise: info@alviautomation.com

Gas Alarm Indoor/Outdoor Ambient Air Quality Monitoring Sensor PM 2.5/P.M10

ALVI – India (http://www.alviautomation.com)  in association with Gas Alarm Systems – Australia (http://www.gasalarm.co.au) take pride to offer Gas Alarm Indoor/Outdoor Ambient Air Quality Monitoring Sensor PM 2.5/P.M10

Particulate matter (PM) is a particle pollution, which is produced in a great number of ways that can be classified into either mechanical or chemical processes. Traditionally, the environmental sciences have divided particles into two main groups PM10 and PM2.5. PM10 is particles between 2.5 and 10 microns (micrometers) in diameter (a human hair is about 60 micron in diameter). PM2.5 is particles smaller than 2.5 microns. PM2.5 and PM10 have different material compositions and can come from different places. The smaller the particle the longer it can remain suspended in the air before settling. PM2.5 can stay in the air from hours to weeks and travel very long distances because it is smaller and lighter.

Continue reading “Gas Alarm Indoor/Outdoor Ambient Air Quality Monitoring Sensor PM 2.5/P.M10”

GSM Remote Controller & Alarm System – ALV-GSM-D-X

ALVI – India (http://www.alviautomation.com)  in association with Gas Alarm Systems – Australia (http://www.gasalarm.co.au) offer GSM Remote Controller & Alarm System – ALV-GSM-D-X

Features:
1) USB port connectivity to PC
2) Multiple Digital Inputs (DI) depending on part number X
3) 2 Relay outputs (1 through digital inputs, 1 through SMS commands)
Overview:
Each DI can be programmed through the PC so that when switched, the controller will send
an SMS notification (configurable in the programming under “Digital Input SMS Alert
Contents” – 32 characters max) to the listed phone numbers in the “SMS Alert Numbers”
column (3 recipients max). Phone messages are also able to be transmitted to a total of 5
phone numbers when the microphone and speaker are connected.
The device has two built in relays: Relay 1 is triggered by both digital inputs where as Relay 2
is controlled using SMS commands. The device can be independently powered by its internal
battery for a maximum of 24 hours.

For more details please find :- alvi-gsm

MSR Germany PolyGard® Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

ALVI  Automation  – India (http://www.alviautomation.com)  in association with Gas Alarm Systems – Australia (http://www.gasalarm.co.au) offer MSR Germany   PolyGard® Single Point Controller SPC-X3-11XX for
Toxic Gases and Oxygen
DESCRIPTION
Gas measuring, monitoring and warning controller based
on state-of-the-art micro-technology with integrated
sensor and internal buzzer for the continuous monitoring
of the ambient air and detecting toxic gases and vapours
or oxygen. The SPC-X3 is provided with an input for one
external analog transmitter. 4 alarm thresholds per
sensor/transmitter are free programmable. Configuration
and operation are possible via the logical, simple system
menu structure without specific programming knowledge.

Continue reading “MSR Germany PolyGard® Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen”

MSR Germany Ammonia NH3 Transmitter – ADT23 1125 Monitoring Sensor

ALVI  Automation – India (http://www.alviautomation.com)  in association with Gas Alarm Systems – Australia (http://www.gasalarm.co.au) offer MSR Germany  Ammonia NH3 Transmitter – ADT23 1125 Monitoring Sensor.

DESCRIPTION:
NH3 transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect ammonia concentrations. A comfortable calibration routine with selective access release is integrated in the transmitter. The ADT-23 possesses a standard analog output, (0) 4–20 mA or (0) 2-10 V DC, and an RS-485 interface. 2 relays with adjustable switching thresholds are available as an option.
APPLICATION:
For detecting leakages in refrigeration plants with ammonia as refrigerant, and also within a wide range of commercial and industrial applications. Due to the standard analog signal and the RS-485 serial interface the NH3 transmitter is compatible to the PolyGard gas controller series MGC and DGC by MSR-E as well as to any other controllers or automation systems.

Continue reading “MSR Germany Ammonia NH3 Transmitter – ADT23 1125 Monitoring Sensor”

MSR Germany PX2-2-xxxx-A LPG Liquefied Gas Sensor For Industrial and Biogas Plants

ALVI  Automation – India (http://www.alviautomation.com)  in association with Gas Alarm Systems – Australia (http://www.gasalarm.co.au) offer MSR Germany  PolyXeta 2 – sensor series for combustible and toxic gases in Zone 1 and Zone 2 with SIL2, ATEX and IEC EX  all 3 approved Certified world’s First Sensor.

Sensor for combustible gases in zone 2
Microprocessor based gas sensor with 4 – 20 mA / RS485-Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect combustible gases and vapors within the lower explosive limit (LEL) by means of a catalytic sensor element (pellistor) or an infrared sensor element. The calibration of sensors without LCD display is carried out via the calibration device Cal PX or the PC software PC-Soft 80. Sensors with LCD display have an integrated calibration routine that is started from outside by a permanent magnet without opening the housing. In case of an alarm or fault the back light of sensors with LCD display changes from green to red.

Continue reading “MSR Germany PX2-2-xxxx-A LPG Liquefied Gas Sensor For Industrial and Biogas Plants”