MSR GasAlarm CO CO2 Sensor Transmitter Approved in Ninyar Jagdalpur Township Project By NMDC LTD Chhattisgarh

We are happy to inform you that Our MSR -GasAlarm CO, CO2 Sensor Transmitter, and GasAlarm PLC HMI  Display Control Monitoring Alarm Systems gets approval in Ninyar Jagdalpur Township Project By NMDC LTD Chhattisgarh by NMDC Ltd, now we are eagerly waiting for the tender opening so that we can provide our best products and services in the reputed projects.

For the Basement Ventilation Systems, Our World Class German Make GasAlarm Carbon Monoxide (CO) Sensor Transmitter, GasAlarm CO2  Carbon Dioxide Sensor Transmitter gets approvals in projects because of its working principle, having high accuracy, easy wiring connections 2 and 3 wire cable connections,  fast response, low maintenance cost, long life, most important we provide  24*7hrs service support.

Also, our best Customized PLC HMI Display Control Alarm Systems gets approval in the project having fully programmed, German make metal enclosure, fully designed with Global Standardized and customized as per the project requirements, more important economical in price and ready to install (Plug and Play).

We are pleased to mention that we had done many ‘reputed and big projects of Basement Car Park Ventilation Systems where we supplied Our CO and CO2 Sensor Transmitter, PLC HMI Control Monitoring Systems, Installation, and Commissioning with Annual Maintenance Services.

For more details please click on demonstration video for Carpak Ventilation Systems – Click here 

Toluene Gas Detector and Monitor

Toluene Gas Detector and Monitor

ALVI Automation (India) Pvt Ltd, a Division of ALVI Technology Pty Ltd, Australia ( Td/As Gas Alarm Systems) is pleased to introduce our world class cutting edge Toluene Gas Detector and Monitor (C7H8)

We are is involved with designing, engineering, implementing, calibrating in the field of Gas Detection Systems, Instrumentation, Field devices, and Automation and several automation industries in the Australasian region including now in India. Our mission is to grow consistently using the best global technologies in products and services offered to customers. We aim to serve and maintain long term relationships by providing the most cost-effective appropriate solutions.

Description:

Toluene gas detector is a highly robust, industrial grade, flameproof, or explosion-proof gas detector for Tolueneleakage detection or LEL monitoring.

The detector is used for online, continuous monitoring of the flammable concentration of Xylene in %LEL or %Vol terms in ambient air or duct or pipeline. It is ATEX, IECEx certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

FEATURES:

  • ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
  • Metrological test & SIL2 safety functions 4–20 mA, RS485 and relay
  • For zone 1 (and also suitable for zone 2) Type “Ex db” with flame-proof enclosure
  • For zone 2: Type “Ex nA” with flame-proof enclosure
  • Continuous monitoring
  • Microprocessor with 12-bit converter resolution
  • Self-monitoring system
  • Easy calibration
  • Calibration service by exchanging the sensor head
  • Proportional 4–20 mA output
  • Serial interface to the control centre
  • Reverse polarity protection
  • Overload protection
  • LCD with status LEDs (optional)
  • Alarm and fault signal relay (optional)

Our Industries:
Our customers comes from various industries like oil/gas, chemical, Manufacturing, petro-chemical, pharmaceutical, building, mining, nuclear, steel, defence, power, water, waste water, mining, cement, diary, automobile etc. 

Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts to info@alviautomation.com, sales@gasalarm.com.au

Be sure, Be safe – Gas Detectors and Alarm Systems

 

Defence CAMP/TENT Protection System For Rapid Deployment Force

Gas Alarm Systems India(http://www.alviautomation.com) in association with Gas Alarm Systems Australia (http://www.gasalarm.co.au) offer MSR Germany Electronics Defence CAMP/TENT Protection System: For Rapid Deployment Force

APPLICATIONS:
Chemical, biological, Explosive Gases Terrorism Gas Threats Very Early Fire Detection Toxic Gas Fumes from bombs, missiles Air Quality in bunkers, shelters Energy Saving / Carbon Credit
Suitable for:
· Rapid Equipping Force in Forward Operating Bases
· Team Putting TENT System / ventilation system

Base camps and other forward deployed operating bases are highly vulnerable to both conventional and asymmetric/terrorist attacks. The frequency of attacks against Allied Forces during Operations Enduring Freedom and Iraqi Freedom indicate that current and future force deployments face an increased probability of such attacks.

The high casualty rates and disruption to operations emphasize the need for enhanced protection of deployed Allied Forces and other peace keeping operations. Conventional security measures provide little or no protection
from improvised lethal attacks. Previous attacks have exposed various weak points and shortcomings in current systems of Camp Protection.

Sensor Platform X (WSB2-X) is a module based software platform for sensor integration, data analysis, alert detection and alert response handling. It provides an automated surveillance system that monitors different kinds of sensors, performs sensor analysis and notifies and aids users in response to critical situations. WSB2-X is a unified management platform providing the customer with a customizable and easy scalable solution to collect physical
security sub-systems into one easy-to-manage system.

Its ability to integrate and manage third-party systems suits the needs of Military Camp Operations by consolidating information from various sources and presenting it in a way that is clear and draws an operator’s attention to the most critical information.

Our main focus areas are listed below, but through our partners we can expand the delivery to fit the customer’s requirements Our strategic partners (Australia, Germany) deliver products, systems and services such as:

Continue reading “Defence CAMP/TENT Protection System For Rapid Deployment Force”

Protection Against Ethyl Alcohol, Ethanol, Methanol, Alcohol Gas Vapours

We know how to solve your gas detection problem! And, we make it easy for you here at Alvi Automation India Gas Alarm Systems for protection from Ethyl Alcohol, Ethanol, Methanol, Alcohol used as a key ingredient in the manufacturing of Hand sanitizer under #COVID -19 pandemic, with taking care of Hand sanitization, social distancing, in a very small way Alvi Automation India can help, assist, design engineer our world-class German gas detection system for all storage area, processing, and manufacturing units of Hand sanitizer for critical life safety and asset protection.

Continue reading “Protection Against Ethyl Alcohol, Ethanol, Methanol, Alcohol Gas Vapours”

Continuous Emission Pollution Monitoring System

ALVI Automation, Jaipur India in association with ALVI Technologies Sydney Australia (Gas Alarm Systems) and MSR Germany can design engineered supply maintain continuous emission monitoring/ surveillance/sentry system. The pollution monitoring sentry is housed in IP65 polycarbonate, glass fiber reinforced, Rough rugged impact-resistant, high-frequency low amplitude, low-frequency high amplitude knocks resistant including UV protection. The system comes with an integral plug-in sensor cartridge of your choice up to max 4 – 32 sensor cartridges can be installed with Standalone, PLC/HMI panel option.

Under the guidance of our Managing director Mr. Alak Jha who has worked in Drager, MSA, Ecotech and with various Australian companies in pollution monitor we were able to supply our Standalone continuous CO gas monitoring system to companies like:

  1. Electrosteel Castings Limited
  2. kamdhenu ispat + 3 more of its division 
  3. Maharashtra steel authority

This was addressed to the pollution control board with their respective state and based on our Standalone type supplied to monitor the CO level they were given license of operation 

With that said the pollution monitoring parameter coming out of industries like power plant (we presume Coal or Gas based) under the PLUME dispersion characteristics studies for:

  1. Fenceline monitoring (4-8 directions)
  2. Rooftop monitoring (MAST) 

The parameter will be like:

  1. Carbon Monoxide (CO) : 0-300 PPM, EC type (other ranges available)
  2. Carbon Dioxide (CO2): 0-2000 PPM, IR type (other ranges available)
  3. Sulphur Dioxide (SO2): 0-20 PPM, EC type
  4. Nitric Oxide (NO): 0-20 PPM, EC type
  5. Nitrogen Dioxide (NO2): 0-100 PPM, EC type (other ranges available)
  6. Ozone (O3): 0-5 PPM, EC type (other ranges available)
  7. Particulate matter 2.5 (PM2.5): 0~1000μg/㎥, Laser type  
  8. Particulate matter 10 (PM10): 0~2000μg/㎥, Laser type
  9. Temperature and Humidity: -20℃~60℃, 0~99%RH
  10. TVOC Data: 0 3.5mg/m3, Metal oxide sensor type
  11. Wind Speed 
  12. Wind direction 
  13. Solar radiation 
  14. Atmospheric pressure

All these parameters can be monitored using our Smart PLC/HMI solution with data logging facilities and Historical data monitoring system with following benefits as follows:

  • 4x Channel interface (can be extended up to 32 for analog type sensor and 96 for Digital type sensor)
  • HMI touch display
  • User-friendly operation
  • Datalog facility with the USB option
  • 5x Digital relay output for external AV alarm
  • 2x Analog output 4-20mA/2-10 VC
  • Data access on mobile with same wifi connection
  • GSM dialler option
  •  Historical graphic display
  • UPS option
  • Solar panel option
  • Option of the panel: Metal/ABS/Polycarbonate/Stainless Steel IP54 

Note: As a plant operator if such parameter is monitored, locked and send to the pollution control board then as per our understanding will be accepted 

Now if you are an operating industry like the power plant, steel plant where they are looking for a pollution monitoring system or PEMS or CEMS in PPB level which is beyond lakhs or crores rupees and beyond our scope as such system needs a dedicated 24×7 maintenance and service such as:

  1. Sampling pump (Breakdown)
  2. Sampling filter (clogging)

Employed with technologies like NDIR, FID, FT, Gas chromatography

In addition, we can also supply Actuators, Float switch, process devices, etc

For more details please feel free to contact us or email us to info@alviautomation.com

Please click on the below Video to know us more

GAS DETECTION FOR DEFENCE APPLICATION

We ALVI Automation India Pvt Ltd, Jaipur a Division of ALVI Technology Pty Ltd, Australia (Td/As Gas Alarm Systems) is involved in design engineering and supply of continuous gas monitoring and gas surveillance systems for prestigious clients and customers. This venture has been setup under Make In India programme in association with Australia. Our systems are being exported to countries like UAE, Cyprus and Qatar. Director of the Company Alak Jha is B.Tech, M.Tech in Electronics from IIT BHU, Business Management from Jadavpur university and Fibre Optics Engineering from Victoria University Australia with 44 years of experience in the field in countries like Germany, Italy, UK, USA, Singapore, Australia, Hongkong, India, Thailand, Indonesia, Malaysia and Sri Lanka. The India team is backed by qualified Electronics, Electrical and Telecommunication Engineers and Technicians. Some of our prestigious clients in India are Honda, Denso, Siemens, Honeywell, Schneider, Bosch, NTPC, Apollo Tyres, Adani, BASF, Voltas, Blue Star etc.

Defence Application: 

1. TENT Protection System (attached): This system will continues monitor the breathable air quality of rapid forward movement of Army personnel in their forward camps from various toxics fumes (Terrorism gas threat, exhaust from rocket and missiles, bombs explosive nuclear).
In 2009 in Jaipur, Rajasthan REL (Rajasthan Electronics) were designing shelters/bunkers for Indian Army. REL had approached us and we had given a demonstration at REL Bunkers to a team headed by Brigadier who had shown great interest in such system.

2. Protection of Army, Navy and Air Force form dangerous risk of CBRNE (Chemical Biological Radio Nuclides and Explosive Gases) threats. We attached Govt. of Australia document where Gas Alarm System, Australia are designated as CBRNE system supplier along with various prestigious research institutes of Australia (See Page # 11 of CBRNE-Homeland Security)

3. Underground Shelter air quality monitoring in underground bunkers. During second World War Germany many such bunkers were designed and engineered giving safety to strategic decision makers who can escape to this bunker, take refuge in such shelter for 30 to 40 days with all safe breathable air quality food, emergency medical, emergency communication etc.


4. Navy HMAS Westralia Fire which killed Navy Personnel from diesel vapour fire and explosion. We can design engineer Safe-T-Sentry system for continuous monitoring of toxic and explosive gases and ensure safety of asset as well as Navy Personnel.

5. Falkland War Naval Ship Disaster: You must be aware of Falkland war between UK and Argentina. This British Naval Vessel was hit by an Argentinian missile, bomb which didn’t explode but the toxic exhaust fumes were sucked by the ship’s air conditioning ventilation system killing many Navy personnel. We can design engineer Safe-T-Sentry system for such toxic and explosive gases and control the ventilation fan to provide safety.

6. Hydrogen Monitoring System for Army, Navy and Airforce for battery room to protect from Hydrogen explosion in Army Datacentre , Communication Centre.

7. Indoor Air Quality Monitoring to keep Defence Hospitals, Defence Headquarters proving safe breathable air, thereby improving productivity and efficiency. (We have supplied many such systems to RBI, SBI, ICICI, Bank of Baroda, IIT Kanpur, IIT Mumbai etc.)


8. Defence ammunition storage fire and explosion millions of Dollars are wasted because of fire in ammunition warehouse, storage areas. Our Safe-T-Sentry VEFSA (Very Early Fire and Smoke Alarm) can provide earliest gas radical detection which are generated in ammunition if overheated. The system will detect the gas radical will generate the alarm to ensure safety of ammunition form fire. Please note by the time smoke and smoke alarm is generated its already too late and the asset cannot be protected.

As an Indian Team We look forward to be associated Govt of India department of defence providing world class cost effective reliable gas monitoring and control system for various CBRNE gases and surveillance to ensure safety of defence personnel and assets.

For More Information please contact us or reash us at info@alviautomation.com

To know us more please watch the video

 

 

 

Protect Further Spread of COVID-19 by Sterilization Control Rooms

After the discharge of COVID-19 patients and instead of using a new facemask and PPE kit, we could reuse by sterilization process in a sophisticated manner by the use of Hydrogen peroxide (H2O2) and Ethylene Oxide (C2H4O) gas dosing.

Also with this safety is our top priority to which we can assist, design engineer, supply and provide technical expertise for Hydrogen peroxide (H2O2) and Ethylene Oxide (C2H4O) Gas monitoring and control with   #criticalsafety interlocking system to sterilize the air quality, safe air, breathing air to ensure safe processes in hospital, laboratories, and research centers.

<

For more details plaese feel free to contact us or email us to info@alviautomation.com

Know us more by simply waching the below video

Oxygen(O2) and Carbon Dioxide(CO2) Gas Monitor in Makeshift Hospitals and Hospital Wards

Under the current pandemic of CORONA VIRUS (COVID -19) affecting nearly every country in the world, health officials are releasing daily updates and guidelines to combat the virus, hence we are here to support by strongly recommending of installation of the Oxygen sensors inside Makeshift Hospitals and Hospital Wards to ensure oxygen enrichment is controlled, Unfortunately, you cannot solely rely on ventilation to ensure a safe working atmosphere. This shall continuously monitor the Oxygen Level inside the confined area and shall initiate ventilation exhaust fan when the oxygen level increases. If the ventilation system fails then an audio-visual alarm shall be initiated, which can be interfaced with the BMS or Fire Alarm system.

Continue reading “Oxygen(O2) and Carbon Dioxide(CO2) Gas Monitor in Makeshift Hospitals and Hospital Wards”

Carbon Monoxide (CO) Sensor Transmitter For Basement Ventilation Automatic Fan Control

We are glad to introduce you to our best, Compact Carbon Monoxide (CO) Sensor Transmitter For Basement Ventilation Automatic Fan Control Systems, Carbon Monoxide Sensor Transmitter which automatically monitors and controls all types of Fan,  from all brands of Fan ( Like Jet Fan, Exhaust Fan, Fresh air Fan )and save your electricity/energy and manpower. Continue reading “Carbon Monoxide (CO) Sensor Transmitter For Basement Ventilation Automatic Fan Control”

Lets Fight Covid19 Together.!!

The FDA has Approved Emergency use of a new coronavirus test that delivers positive results in 5 minutes and negative results in 13 minutes, with this said all the Hospitals, testingcenters, testlabs, RehabilitationCenters shall be receiving this test facility, along with this we would highly recommend to monitor and control safe breathing zones, air quality index with automatic control of HVAC system, Ventilation Air Control by controlling of fresh air fans, AHU, etc to keep germs and virus at bay and keep our environment safe to carry out the testing efficiently and we have to ensure that these covid19 Hospitals, test facilities are maintained with good temperature, humidity with negative pressure controller environment for which ALVI Automation – GasAlarm India would love to assist you and lets come out from this novelcoronavirus together. iaq  emergency safetyfirst indoorairquality  lifesafety gasdetection safetytraining firesafety energysaving alarmsystems fireprotection controlsystems machinesafety Gas Alarm Systems Alvi Gas MSR-Group GmbH Indian Army GE Healthcare

please feel free to reach us at info@alviautomation.com or contact us

Why Discrete Gas Detection System is Better Than Sampling System.?

In consultation with our Director Mr. Alak Jha from Sydney Australia who has been working in this field since 40 years and worked on this sequential sampling system while he was in Drager, MSA finds that none of the sequential systems works with satisfactory including coal yard application using the Ex-Proof pump by “Miahik” as regular service, maintenance, and replacement of spares is very essential who’s cost factor calculation is almost 3-4 times higher than the discrete-continuous type of system.

Hence would highly recommend going this discrete type of continuous monitoring system with data logging facilities for Application like Fruit Ripening, Cold Stores, Battery room, Server rooms, UPS Rooms, Electrical rooms, etc  

Few things that support the above-said points as follows for Sequential monitoring system :

Problems:

  1. End line filter clogging (Dust filter gets clogged since in India we have a very fine trace of dust available which causes clogging)
  2. Condensate catch point (while drawing samples from long distance which includes Air, moisture, humidity, gases are compressed in a thin pipe which causes condensation)
  3. The pneumatic line is Difficult to maintain leak-free
  4. Tremendous Delay in sequential sampling time which may vary from 5-15 mins depending on the distance
  5. Cost and maintenance factor shall be increased about 3 to 5 time than the discrete type system

Solution:

We would highly recommend using a discrete-continuous sensor transmitter with data logging and remote mobile monitoring and control facility

 

Should you have any questions please feel free to contact us

We look forward to hearing from you soon

please feel free to reach us at info@alviautomation.com or contact us

LPG PNG CNG Gas Leak Detector for Reputed Hotel’s Gas Bank and Kitchen Area

We are pleased to inform you that we have successfully completed Supply installation and commissioning of our cutting edge MSR Ex-proof LPG gas leak detection system for LPG storage and Kitchen area application, in ITC – Rajputana One of the reputed 5-star hotels of Rajasthan by taking consideration of hashtagHAZOP & hashtagHAZAN global criteria, we were able to deliver our PX2 series Flame-proof LPG gas detector by MSR Germany which is one of the Best German companies that provides Fixed Gas Leak detectors having global certifications ATEX, IEC-Ex , SIL2, CE. 

ALVI Automation (India) Pvt Ltd in association with ALVI Technologies Pty Ltd  presents to you Online  LPG Gas Leak Detector and Gas Monitoring System For Hospital  And Hotel Application: 

For LPG PNG CNG pipeline system, Gas cylinder storeroom, and kitchen application: 

    1. Aim: To identify potential gas leaks from pipeline or gas cylinder
    2. Solution: By installing LPG/PNG/CNG gas sensor transmitter along with control and monitoring system and using set points as per global standards to generate an audio-visual alarm and BMS connectivity

Our Flammable Gas Detector has the following Features : 

Continue reading “LPG PNG CNG Gas Leak Detector for Reputed Hotel’s Gas Bank and Kitchen Area”

Importance Of Calibration Services for Gas Detectors

Avoid Life-Threatening and Critical Situations by Periodic Re-Calibration of MSR Smart Gas Detectors

the system is in alarm, the performance of any audio/visual alarms, signal to BAS or Fire panel.

When the Gas sensor is new it comes out with factory calibration which is done under controlled environments and therefore the Gas sensor will behave according to the characteristics stated in the manufacturer specifications. During use, however, its behavior will gradually diverge from the stated specifications for a variety of reasons. Such reasons include:

  1. Mechanical/Component wear
  2. Effect of dust & dirt
  3. Fumes and chemicals in the operating environment
  4. Changes in weather
  5. Bugs and spiders
  6. Humidity.

The rate of divergence from standard specifications varies according to:

  1. Type of instrument/sensor
  2. Frequency of usage,
  3. The severity of the operating conditions.

There comes a time when the characteristics of the Gas sensor will have drifted from the standard specifications by an unacceptable amount. When this situation is reached, it is necessary to re-calibrate the sensors to the standard specifications. Such re-calibration is performed by adjusting the sensor readings output until it matches the reference gas applied to it Digitally.

Frequency of Calibration

The frequency of calibration depends upon all the above-stated factors. Sensors should be bump tested/calibrated every 6 – 12  months. This allows the sensor to perform optimally and reduce any false alarms and errors. It is recommended that at every calibration/testing sequence of programming should be checked which consists of all the equipment terminated into the gas monitoring system. Mainly these are the correct operation of exhaust fans and fresh air inlet dampers when the system is in alarm, the performance of any audio/visual alarms, signal to BAS or Fire panel.

All Gas sensors are equipped to be calibrated for a certain number of times. This derives the life expectancy of the sensor cell. All sensors have an expiry date or better-called shelf life. This shelf depends upon the gas type sensor is detecting and type of sensor. Under certain conditions, the life span range of some of the common gas type sensors by MSR Germany GmbH are as follows:

  • Carbon monoxide (CO): > 6 years
  • Nitrogen dioxide (NO2): > 2 years
  • Oxygen (O2): >2 years to >7 years
  • Combustible (CH4, H2, etc.):  >3 years

In the end, We would like to conclude that, as these systems are located in your building/ Industrial premises, it is advisable to educate supervisors or maintenance personal. This can avoid many incidents and damages. Proper commissioning of new systems, field calibration of new/existing systems, an inspection of a sequence programmed (standard or customized) and inspection of all equipment (ventilation, audio/visual alarms, BAS, Fire panel) tied with our gas monitoring system should be checked.

The best preparation for tomorrow is doing your best today. – H. Jackson Brown Jr.

For more details please email us to into@alviautomation.com or contact us 🙂

CO – Carbon Monoxide Sensor for Basement car Parking

When it comes to CO – Carbon Monoxide Sensor for Basement Car Parking MSR Germany/GASAlarm make the GAS-CO-300-D model is the Best techno-commercial option in the International HVAC market.

Now available with a special discounted price for the Indian market with the following details :

SPECIFICATIONS:- 

  • Sensor Model Available in Stock: – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 30 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in: IP65 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years  )

Continue reading “CO – Carbon Monoxide Sensor for Basement car Parking”

Car Parking CO Gas Monitoring and Fan Control Systems

When it comes to Carbon Monoxide Detection in Car Parking CO Gas Monitoring and fan control Systems, Our  European Standard  MSR CO GAS-CO-300-D Sensor Transmitter has great demands in the global market.

Now available with a special  promotional discounted price for the Indian market with the following details :

Ideal for :
Parking area, garages, chiller rooms, and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points:- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smoldering fire and smoke detection.
  • VEFSA system (very early fire and smoke alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in Stock: – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 30 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in: IP65 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 935m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output, also available in 2-10VDC
  • Flammability: – UL 94: V2
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval:  CE/ UL Enclosure.