IECEx, ATEX, SIL2 R507a Gas Detector, Monitor
By ALVIDESCRIPTION
Fixed PolyXeta 2 Gas Alarm Devices of the
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for continuous monitoring of the ambient air to detect R507a Freon gases and refrigerants in higher concentration range for use in the hazardous areas of zones 1 and 2 according to Directive 2014/34/EU.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Built for standard output of 4-20 mA analog signal output, this transmitter is compatible with the PolyGard series controllers the MGC/DGC as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts to info@alviautomation.com, sales@gasalarm.com.au
Be sure, Be safe – Gas Detectors and Alarm Systems
Description
DESCRIPTION
Fixed PolyXeta 2 Gas Alarm Devices of the
- PX2-1 series with Ex db protection for Zone 1 and 2
- PX2-2 series with Ex nA protection only for Zone 2
Designed for continuous monitoring of the ambient air to detect R507a Freon gases and refrigerants in higher concentration range for use in the hazardous areas of zones 1 and 2 according to Directive 2014/34/EU.
FEATURES:
- ATEX and IEC Ex certificates MSR-Electronic for electrical Ex protection
- PX2-1 for zone 1 (and also suitable for zone 2): Type “Ex db” with flame-proof enclosure
- PX2-2 for zone 2: Type “Ex nA” with flame-proof enclosure
- Enclosure: additional CSA certificate for Class I, Div. 1
- Continuous monitoring
- Microprocessor with 12-bit converter resolution
- Self-monitoring system
- Easy calibration
- Calibration service by exchanging the sensor head
- Proportional 4–20 mA output
- Serial interface to the control center
- Reverse polarity protection
- Overload protection
- LCD display with status LEDs (optional)
- Alarm and fault signal relay (optional)
Our Industries:
- Fertilizer & chemical industry
- Oil & gas, refinery
- Solvent and paint unit
- Paint booth
- Explosive manufacturing
- Chemical
- Manufacturing
- Petrochemical
- Pharmaceutical
- Building/Commercial Automation
- Mining, Nuclear, Steel, Defense, Power, Water, Wastewater cement, Dairy, Automobile, etc.
Built for standard output of 4-20 mA analog signal output, this transmitter is compatible with the PolyGard series controllers the MGC/DGC as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts to info@alviautomation.com, sales@gasalarm.com.au
Be sure, Be safe – Gas Detectors and Alarm Systems