Lets Fight Covid19 Together.!!

The FDA has Approved Emergency use of a new coronavirus test that delivers positive results in 5 minutes and negative results in 13 minutes, with this said all the Hospitals, testingcenters, testlabs, RehabilitationCenters shall be receiving this test facility, along with this we would highly recommend to monitor and control safe breathing zones, air quality index with automatic control of HVAC system, Ventilation Air Control by controlling of fresh air fans, AHU, etc to keep germs and virus at bay and keep our environment safe to carry out the testing efficiently and we have to ensure that these covid19 Hospitals, test facilities are maintained with good temperature, humidity with negative pressure controller environment for which ALVI Automation – GasAlarm India would love to assist you and lets come out from this novelcoronavirus together. iaq  emergency safetyfirst indoorairquality  lifesafety gasdetection safetytraining firesafety energysaving alarmsystems fireprotection controlsystems machinesafety Gas Alarm Systems Alvi Gas MSR-Group GmbH Indian Army GE Healthcare

please feel free to reach us at info@alviautomation.com or contact us

Why Discrete Gas Detection System is Better Than Sampling System.?

In consultation with our Director Mr. Alak Jha from Sydney Australia who has been working in this field since 40 years and worked on this sequential sampling system while he was in Drager, MSA finds that none of the sequential systems works with satisfactory including coal yard application using the Ex-Proof pump by “Miahik” as regular service, maintenance, and replacement of spares is very essential who’s cost factor calculation is almost 3-4 times higher than the discrete-continuous type of system.

Hence would highly recommend going this discrete type of continuous monitoring system with data logging facilities for Application like Fruit Ripening, Cold Stores, Battery room, Server rooms, UPS Rooms, Electrical rooms, etc  

Few things that support the above-said points as follows for Sequential monitoring system :

Problems:

  1. End line filter clogging (Dust filter gets clogged since in India we have a very fine trace of dust available which causes clogging)
  2. Condensate catch point (while drawing samples from long distance which includes Air, moisture, humidity, gases are compressed in a thin pipe which causes condensation)
  3. The pneumatic line is Difficult to maintain leak-free
  4. Tremendous Delay in sequential sampling time which may vary from 5-15 mins depending on the distance
  5. Cost and maintenance factor shall be increased about 3 to 5 time than the discrete type system

Solution:

We would highly recommend using a discrete-continuous sensor transmitter with data logging and remote mobile monitoring and control facility

 

Should you have any questions please feel free to contact us

We look forward to hearing from you soon

please feel free to reach us at info@alviautomation.com or contact us

LPG PNG CNG Gas Leak Detector for Reputed Hotel’s Gas Bank and Kitchen Area

We are pleased to inform you that we have successfully completed Supply installation and commissioning of our cutting edge MSR Ex-proof LPG gas leak detection system for LPG storage and Kitchen area application, in ITC – Rajputana One of the reputed 5-star hotels of Rajasthan by taking consideration of hashtagHAZOP & hashtagHAZAN global criteria, we were able to deliver our PX2 series Flame-proof LPG gas detector by MSR Germany which is one of the Best German companies that provides Fixed Gas Leak detectors having global certifications ATEX, IEC-Ex , SIL2, CE. 

ALVI Automation (India) Pvt Ltd in association with ALVI Technologies Pty Ltd  presents to you Online  LPG Gas Leak Detector and Gas Monitoring System For Hospital  And Hotel Application: 

For LPG PNG CNG pipeline system, Gas cylinder storeroom, and kitchen application: 

    1. Aim: To identify potential gas leaks from pipeline or gas cylinder
    2. Solution: By installing LPG/PNG/CNG gas sensor transmitter along with control and monitoring system and using set points as per global standards to generate an audio-visual alarm and BMS connectivity

Our Flammable Gas Detector has the following Features : 

Continue reading “LPG PNG CNG Gas Leak Detector for Reputed Hotel’s Gas Bank and Kitchen Area”

Importance Of Calibration Services for Gas Detectors

Avoid Life-Threatening and Critical Situations by Periodic Re-Calibration of MSR Smart Gas Detectors

the system is in alarm, the performance of any audio/visual alarms, signal to BAS or Fire panel.

When the Gas sensor is new it comes out with factory calibration which is done under controlled environments and therefore the Gas sensor will behave according to the characteristics stated in the manufacturer specifications. During use, however, its behavior will gradually diverge from the stated specifications for a variety of reasons. Such reasons include:

  1. Mechanical/Component wear
  2. Effect of dust & dirt
  3. Fumes and chemicals in the operating environment
  4. Changes in weather
  5. Bugs and spiders
  6. Humidity.

The rate of divergence from standard specifications varies according to:

  1. Type of instrument/sensor
  2. Frequency of usage,
  3. The severity of the operating conditions.

There comes a time when the characteristics of the Gas sensor will have drifted from the standard specifications by an unacceptable amount. When this situation is reached, it is necessary to re-calibrate the sensors to the standard specifications. Such re-calibration is performed by adjusting the sensor readings output until it matches the reference gas applied to it Digitally.

Frequency of Calibration

The frequency of calibration depends upon all the above-stated factors. Sensors should be bump tested/calibrated every 6 – 12  months. This allows the sensor to perform optimally and reduce any false alarms and errors. It is recommended that at every calibration/testing sequence of programming should be checked which consists of all the equipment terminated into the gas monitoring system. Mainly these are the correct operation of exhaust fans and fresh air inlet dampers when the system is in alarm, the performance of any audio/visual alarms, signal to BAS or Fire panel.

All Gas sensors are equipped to be calibrated for a certain number of times. This derives the life expectancy of the sensor cell. All sensors have an expiry date or better-called shelf life. This shelf depends upon the gas type sensor is detecting and type of sensor. Under certain conditions, the life span range of some of the common gas type sensors by MSR Germany GmbH are as follows:

  • Carbon monoxide (CO): > 6 years
  • Nitrogen dioxide (NO2): > 2 years
  • Oxygen (O2): >2 years to >7 years
  • Combustible (CH4, H2, etc.):  >3 years

In the end, We would like to conclude that, as these systems are located in your building/ Industrial premises, it is advisable to educate supervisors or maintenance personal. This can avoid many incidents and damages. Proper commissioning of new systems, field calibration of new/existing systems, an inspection of a sequence programmed (standard or customized) and inspection of all equipment (ventilation, audio/visual alarms, BAS, Fire panel) tied with our gas monitoring system should be checked.

The best preparation for tomorrow is doing your best today. – H. Jackson Brown Jr.

For more details please email us to into@alviautomation.com or contact us 🙂

Save Your Chemical Store Rooms from Hazardous Incidents Using Smart GSM Based System

Introducing our Smart GSM Remote Controller & Alarm System 

Typical applications
The voltage-free relays can be used with our other GC-series controllers to add remote functionality to a control system. The device can be paired with other controllers as well and a range of application for the device is mentioned below:
1. Security Alarm System applications;
2. Supervision and monitoring of alarm systems
3. Automatic monitoring system;
4. Vending Machines;
5. Pumping Stations;
6. Buildings and Real Estate;
7. Weather Station’s remote control and data logging;
8. River Monitoring and Flood Control remote control;
9. Oil and gas pipelines remote control and data logging;
10. Corrosion protection
11. Valve controls;
12. Wellheads;
13. Energy-saving, street lights control system;
14. Tanks, levels, temperatures, water leakage applications;
15. Transformer stations; 16. Unmanned machine rooms;
17. Control room application;
18. PLC and Automation System, M2M;
19. GSM Access Control System, GSM Gate Opener, etc.

GMS design

Click here to download the datasheet 

please reach us at info@alviautomation.com for more details 

CO – Carbon Monoxide Sensor for Basement car Parking

When it comes to CO – Carbon Monoxide Sensor for Basement Car Parking MSR Germany/GASAlarm make the GAS-CO-300-D model is the Best techno-commercial option in the International HVAC market.

Now available with a special discounted price for the Indian market with the following details :

SPECIFICATIONS:- 

  • Sensor Model Available in Stock: – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 30 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in: IP65 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years  )

Continue reading “CO – Carbon Monoxide Sensor for Basement car Parking”

Car Parking CO Gas Monitoring and Fan Control Systems

When it comes to Carbon Monoxide Detection in Car Parking CO Gas Monitoring and fan control Systems, Our  European Standard  MSR CO GAS-CO-300-D Sensor Transmitter has great demands in the global market.

Now available with a special  promotional discounted price for the Indian market with the following details :

Ideal for :
Parking area, garages, chiller rooms, and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points:- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smoldering fire and smoke detection.
  • VEFSA system (very early fire and smoke alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in Stock: – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two and Three-wire sensor
  • Response time T90:-  ≤ 30 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in: IP65 (Flameproof and weatherproof )
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 12 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 935m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output, also available in 2-10VDC
  • Flammability: – UL 94: V2
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval:  CE/ UL Enclosure.

LPG Detector – Liquified Petroleum Gas Leak Detection Systems

GasAlarm Systems India pleased to Introduce Highly Accurate LPG Gas Leakage sensor transmitter/detector/analyzer in association with ALVI Technologies- Australia &  MSR Germany having following features:

  • Measuring range: 0-100% LEL (lower explosive limit), 0-100% Vol (analysis)
  • Available Technology: Pellistor / catalytic bead (flammability monitoring), Infra-red
  • Output: 4-20mA, 0-10V, RS485 Modbus, Lon, BACnet
  • Enclosure: IP44, IP54, IP65, Flameproof, Stainless Steel
  • Certificate: UL 61010, UL 2075, ATEX EExd, ATEX EExn, CE
  • Mounting: wall mountable, duct mountable
  • Installation area: safe area, hazardous area, explosion-proof
  • Reverse polarity protected
  • Poisoning protected
  • Low flashing temperature for longer sensor
  • Modular architecture
  • Manual calibration
  • Expected life: 3 years-15 years
  • Low response time

Application areas: Kitchen, gas bank, bottling plant, booster station, gas store, pharmaceutical, cylinder store, gems processing, heat processing, furnace, engine room, testing rooms, automobile, defense, warship, annealing plant, chemical plants, oil & gas, fire safety, domestic gas pipeline, kitchen, refinery, food processing, cement, bearing, machine industry, swimming pool, combustion area, bakery, commercial, hotels, mines, confined space, gasifier, stockyard, oil wells, biogas plant, landfill, boiler plant, thermal power plants, etc

Gas type available: combustible gas detector, confined space gas detector, gas detection system, gas detectors, gas analyzers, exhaust gas analyzers, biogas analyzers, stack gas analyzer, catalytic gas sensor, combustible gas sensor, gas sensors, hydrogen gas sensor, methane detector, LPG bottling plants, LPG burners, LPG cylinder plant, LPG fuel tank, LPG gas leakage sensor, gas train, LPG gas tanker, LPG station, LPG vaporizer, natural gas alarm, natural gas plants, combustion analyzer, biogas generation plant, biogas generator, biogas power generation plant, biomass gasifier, propane vaporizers.

 

For More details please feel free to contact us – Infor@alviautomation.com

“Best Selling” Carbon Monoxide Detector GAS-CO-300-D “on-Sale”

Globally “Best  Selling ” Carbon Monoxide Detector  GAS-CO-300-D  “on-sale ” for the limited period till stocks clear.

German Made GasAlarm model number- GAS-CO-300-D Carbon Monoxide Sensor Transmitter having an excellent high-quality Electrochemical Sensing technology, Top Measurement accuracy, fast response, long service life sensor, two core wiring connection, up to 80% energy-saving, protection class IP65 in the economical discounted price range.

Carbon Monoxide Sensor Transmitter Petrol Diesel Vapour Sensor Transmitter Oxygen Sensor Transmitter

Ideal for :
Basement Car Parking area, garages, chiller rooms, and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant, thermal power plants, flour mills,
powder industries.

Key Points:- 

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smouldering fire and smoke detection
  • VESFA system (very early smoke and fire alarm)

SPECIFICATIONS:- 

  • Sensor Model Available in:  – GAS-CO-300-D
  • Measuring Gas: Carbon Monoxide, Enhanced CO + radicals Detection.
  •  Sensor element (cell):- Electrochemical Diffusion, Electrolyte type Gel-based (no leak, no membrane rapture, no orientation problem & no false alarm)
  •  Measuring Range: – 0-300 ppm (Standard)
  • Connection: – Two
  • Response time T90:-  ≤ 50 Sec
  • Warm-up time (First Time):- ≤ 3 Min.
  • Protection Class Available in IP65
  • Stability & resolution: – ± 3 ppm
  • Sensor life expectancy:- ≥ 6 years (Site Feedback ≥ 11 Years  )
  • Calibration Interval: 1 Year.
  • Sensor Coverage Area: – 700 m2 to 750m2, ideal condition.
  • Humidity non-condensing : 15-90% RH
  • Working temperature:–10°C to 50°C
  • Power supply:-  18 – 28 VDC ( Overload protected)
  • Analog output signal:- Standard: 4-20 mA Linear Output
  • Warranty: 12 Month only on manufacturing defects
  • Guidelines Approval: CE, UL

Please watch simple demo of our Gas leak Control and Monitoring System click here

Ethylene (C2H4) Gas Detector for Fruit Ripening Application

We ALVI India and GasAlarm Systems Australia Pleased to introduce our one of best and Economical Sensor Transmitter for the Food Processing Unit.

Globally “Best  Selling ” Economical  MC2-D-S2189-A-0-P-00 Ethylene Sensor Transmitter for Fruit Ripening Chamber and Ethylene Gas Generation Plant    “on-sale ” for the limited period till stocks clear.

Ethylene (C2H4) Gas Sensor Transmitter
Model no: MC2-D-S2189-A-0-P-00
Make: MSR Germany GmbH

With Features :
• Range: 20-2000 ppm C2H4
• Sensor Cell: Semiconductor
• Power Supply: 24 VDC
• Analog Output:4-20mA/2-10 VDC
• Housed in IP65 Polycarbonate enclosure
• Response time: T90 ≤ 10 s
• Life ≥ 5 years
• Wall mounting installation
• Calibration Interval: 1 year
• Continuous monitoring
• Low Zero point drift
• Poisoning stable
• Long-life sensor
• Short circuit and overload protected
• Reverse polarity protected
• Easy maintenance and calibration

* For More details please refer datasheet