Hydrogen Cyanide Gas Sensor Transmitter
By ALVIμGard®2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect HCN Toxic gas.
The MC2-X-E1183–X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical HCN sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
Digital measurement value processing incl. temperature compensation- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts to info@alviautomation.com, sales@gasalarm.com.au
Be sure, Be safe – Gas Detectors and Alarm Systems
Description
μGard®2 (developed by MSR) is the new exchangeable sensor unit that is capable of digital value processing, temperature compensation, and self-control for the continuous monitoring of the ambient air to detect HCN Toxic gas.
The MC2-X-E1183–X-X is a sensor element at its core with many possible customizations. The beauty of the microgard 2 system is a microcontroller integrated into the Electrochemical HCN sensor module. The integrated temperature compensation ensures the highest accuracy, selectivity and reliability despite the long calibration interval. The microcontroller calculates a linear 4-20 mA (or 2-10V) signal out of the measurement signal of the Semi-Conductor sensor and also stores all relevant measured values and data of the sensor element.
Calibration is a breeze with this modular design allowing easy swapping of the sensor unit or via the use of the integrated calibration routine directly at the system.
FEATURES
Digital measurement value processing incl. temperature compensation- Data / Measured values stored in the microcontroller on the sensor unit allowing easy swap of an old sensor with a newly calibrated sensor.
- High accuracy, selectivity, and reliability
- Low zero point drift
- Sensor life time: Refer the datasheet
- SIL2 Compliant development process
- Easy maintenance and calibration by the exchange of the sensor module or by integrated on-site calibration.
- 4-20 mA (or 2-10V) analog output with selectable signal output for special mode, fault etc.
- Reverse polarity protected, overload and short-circuit proof
- Integrated heating down to -35°C
- Optional:
- Without housing
- With housing Plastic: Type D, 94 x 65 x 57 mm
- 4-20 mA output signal
- 2-10 V output signal
- With display for values and operation, 2x open collector for horn and warning lamp
- Conformity to:
o EN 378
o EN 45544
o EN 50104 (for O2)
o EN 50271
o EN 50545
o EN 61010-1
o ANSI/UL 61010 1
o CAN/CSA-C22.2 No. 61010-1
• Duct mounting kit (accessory)
Built for standard output of 4-20 mA / 2-10V analog signal output, this transmitter is compatible with the PolyGard 2 series controllers & Sensor Boards as well as any other electronic control or automation system.
Should you have any questions or concerns regarding this matter, please feel free to contact us or reach our experts to info@alviautomation.com, sales@gasalarm.com.au
Be sure, Be safe – Gas Detectors and Alarm Systems