JOLA- Floating switches For Mines

ALVI Automation in association with ALVI Australia and Jola Germany takes pride to present  the Jola Float Switches in India .

For mounting from the side or from the top.
To ensure a correct switching the cable must be fixed at the required height:
• using a stuffing gland, for example, in the case of mounting from the side or
• using a fixing weight, for example, in the case of mounting from the top.
These units are not suitable for use in turbulent liquids (e.g. in stirrer tanks).

Technical data :  SI/SSX/LF/20/1/K/…/Variant 0 I M2 / II 2 G …
Application : for use in intrinsically safe circuits in mines susceptible
to firedamp or in potentially explosive atmospheres
zone 1 and 2;
EC  certificate :  INERIS 03 ATEX 0149
Operating principle : Ball-operated microswitch, potential-free changeover contact.
Float protection class : IP68
Max. immersion depth
of the float max. 10 metres head of water at + 20°C
Connecting cable /application range /temperature range :  black TPK cable, 4 G 0.75 (SI/SSX/LF/20/1/K/TPK/…):
For use in:
water / used water / slightly aggressive liquids,
specific gravity: ≥ 0.7 g/cm³

Temperature : Between 0°C and + 60°C
Black CM cable, 4 G 0.75 (SI/SSX/LF/20/1/K/CM/…):
For use in:
water / certain acids / certain lyes, specific gravity: ≥ 0.8 g/cm³

Temperature : Between 0°C and + 60°C

Continue reading “JOLA- Floating switches For Mines”

Early Fire Warning Sensor-in Electrical Switch Rooms, Sub-Station, Electrical Panels

ALVI India in association with ALVI Australia and MSR Germany feel honour to published Very Early Fire Warning Sensor for Electrical Switch Rooms, Sub-Station, Electrical Panels in India to stop the hazardous incident takes place due to electrical short circuit.

APPLICATIONS:
Server rooms VEFSA – Early Fire Warning Early Fire Warning before breakdown.
Switch Gear Rooms Electrical Panels Mission Critical Asset Safety / OH&S
Background:
On overheating of electrical or electronics cabinets, switchgear, cables (due to short circuit, earth leakage hot,spots, over-load, under-rated design) host of mixed gases like HCl, CO, CO2, and other solvents/vapours are
generated much before smoke. Our Mixed Gas Sensors can pick-up these host of mixed gases generated on overheating
of these electrical items, electronic items. Further PVC wires/cables give HCl, smouldering electrical fires in
transformers, cables give CO, CO2 (products of combustion gases).

Electrical Switch Rooms, Sub-Station, Electrical Panels, Computer Rooms, Telecommunication Centres use host of
electronic components, electrical parts, coolant, PCB lacquers, Polymers, PCB Varnish, conformal coat, lead, PVC

Continue reading “Early Fire Warning Sensor-in Electrical Switch Rooms, Sub-Station, Electrical Panels”

Portable PH-Meter by Greisinger/Germany

ALVI AUTOMATION INDIA PVT LTD (www.alviautomation.com) a Div of ALVI TECHNOLOGY PTY LTD(www.alvi.com.au) also trading as       GasAlarm Systems(www.gasalarm.com.au) presents Portable PH-Meter by Greisinger/Germany

Model no : GPH 114

pH-meter ready for use incl. pH-electrode type GE 114 and battery.

Specifications:

  • Measuring range: 0.00 … 14.00 pH with standard pH-electrode type GE 114
  • Resolution: 0.01 pH
  • Accuracy (device): ± 0.02 pH ± 1 digit (at nominal temperature 25 °C)
  • Working conditions: 0 … 45 °C; 0 … 80 % RH (non condensing)
  • Storage temperature: -20 … +70 °C
  • Connection: BNC Bajonett
  • pH-electrode: GE 114 (standard electrode)
  • Combination electrode with GEL-electrolyte. Measuring
  • range: 0-14 pH, temperature 0-60 °C, conductivity >200 μS/cm
  • Input resistance: approx.1012 Ohm
  • Display: 3½-digit LCD display, 13 mm high
  • Calibration: 3 turning knobs for: 1. temperature compensation 0-90 °C,
  • 2. pH 7 value and 3. pH X value (e.g. pH 1,09, pH 4, pH 10 or
  • pH 12, depends on working range)
  • Power supply: 9 V battery
  • Battery service life: approx. 200 operating h
  • EMC: The device corresponds to the essential protection ratings established in the Regulations of the Council for the Approximation of Legislation for the member countries regarding electromagnetic compatibility (2004/108/EG) Additional fault: <1 %
  • Housing: Impact resistant ABS
  • Dimensions: 106 x 67 x 30 mm (H x W x D)
  • Weight: approx. 200 g (incl. battery and electrode)
  • Scope of supply: Device, pH-electrode GE 114, battery, manual

Click here to access the datasheet

Fire & Smoke Detection with MSR Germany Sensor.

Gas Alarm offers world-class solutions and products for earliest and accurate fire and smoke monitoring, without giving any false alarms. These products offer warning signals better and earlier than costliest system like VESDA, optical sensors etc.
Very Early Fire & Smoke Detector, Gas Alarm offer one of the best smoke & fire detector which can be installed at any environment eg. coal mines, flour mills, pharma, clean rooms, oil & gas, etc. Early Fire detector / transmitter (VEFSA) is designed for detection of earliest sign of smoke & fire, and hence thereby offering better warning detection system, better than VESDA. Using unique detection technology and method, VEFSA offer best fire & smoke detection, without false alarm. These can be implemented at any location with quite easy. VEFSA is compatible for integration to any fire panel and alarm system, be to Siemens, Honeywell, GE etc. VEFSA works in environment and application where none of the conventional smoke & fire detection can work. VEFSA, though being more effective than some of the expensive solutions, it even more easy to implement and integrate, without having much design knowledge.

As VEFSA provide earliest signs of smoke & fire, it buy the critical time needed to investigate an alarm and initiate an appropriate response to prevent injury, property damage or business disruption. VEFSA offer various levels of integrity monitoring to ensure an alert is raised at any time, depending upon criticality of the application and environment. This is not the case with passive devices that are generally only electrically monitored with no ability to determine if smoke can actually reach the detection element. VEFSA offer dual level of alarms which are configurable. This VEFSA to provide very early warning of an event, prompting investigation at the earliest smouldering stage of a fire when it is easily addressed. Other alarm levels may be configured to provide fire alarm inputs to fire systems as well as releasing suppression systems. VEFSa alarm sensitivities are configurable and can be programmed to levels ranging from thousands of times more sensitive than a conventional detector, to much less sensitive.

VEFSA can be implemented across a wide (all) range of industries and applications, with no effect of dust, moisture, vibration, temperature, weather, pressure etc:
Continue reading “Fire & Smoke Detection with MSR Germany Sensor.”

FISCHER – DA55 – ABSOLUTE PRESSURE GUAGE

Product Description

FISCHER – DA55 – ABSOLUTE PRESSURE GUAGE

Absolute pressure guage is used for monitoring gaseous and liquid media.  The unit is in particular characterized by the fact that it is available in optionally stainless steel or HASTELLOY® and therefore qualifies for diverse and aggressive media. As an option, the pressure gauge can also be equipped with limit signal switches as auxiliary electric components. Measuring ranges from 0..25 mbar abs to 0..6 bar abs serve to cover a wide measuring range.

Applications includes monitoring of

  •  vacuum pumps
  •  centrifuges,
  •  packaging machines
  •  process flows in the process industry.

Gas Warning Systems for Maximum Safety

ALVI Automation in association with MSR-Electronic Germany  provides reliable sensors, controllers and warning devices for refrigeration systems. The product line PolyGard®2 ensures reliable monitoring of leakages at all times and thus protects not only the health of persons but also the operation of the refrigeration systems. The simple Plug & Play sensor technology (X-Change) also allows you to save time and costs for maintenance significantly. The sensors are available for all common refrigerants.

Advantages when using the certified gas warning systems from MSR-Electronic:

 Compliant with EN 378-1 and many more

 SIL2 compliant according to IEC 61508

 Suitable for large and small systems

 The X-Change exchangeable sensor makes calibration of the sensors easier

 Alarm thresholds and interfaces freely selectable

The door-entry modules provide maximum safety in addition: If the gas concentration increases in closed buildings, for example in cooling rooms, the doors can only be opened in one direction: from the inside to the outside. This ensures that people can only move out of the hazardous area, but they can never move in.

The Bavarian company MSR-Electronic, headquartered in Pocking, develops and produces perfectly matched sensors, controllers and warning devices, which can be combined in many ways into high quality gas warning systems. Optimum protection for people and installation is thus ensured in enclosed areas in critical situations. Due to the individual configuration and the flexible integration, solutions from MSR Electronic are used worldwide in a variety of applications.

On our homepage (www.alviautomation.com) you will find details about all products.

Industrial Gas Detection for Safe Protection in Hazardous Conditions

Most of the manufacturing industries  in the world, be it food & beverage production, mining or automotive, pharma industry, Oil & Gas, Refineries and Petroleum  industries  use processes that can produce dangerous levels of poisonous gases. Some gases are  easily recognized by  their pungent smell, but some are odourless and tasteless, making them particularly difficult to identify. All  around the world, a large number of people die every year as a result of inhaling toxic gases encountered in their various fields of operations and several explosions have occurred due to combustible gas leaks. Basically there are three hazard categories:

  • Combustible Gases: Dangers of explosion
  • Toxic Gases: Danger of poisoning
  • Oxygen: Danger of suffocation due to Oxygen deficiency or fire hazard due to Excess Oxygen

Wherever such hazardous gases are stored, bottled, processed or transported, safety is at risk.

The dangers posed by such toxic and combustible gases are very significant hence there is a  need for gas detection  to keep the work-place and the workers safe.

Continue reading “Industrial Gas Detection for Safe Protection in Hazardous Conditions”

Custom Built FISCHER Differential Pressure Switch model no DS1302VAYYYD0064

ALVI  Automation – India (http://www.alviautomation.com) offers Custom Built FISCHER/Germany Differential Pressure Switch model no DS1302VAYYYD0064

Principles of Operation

This differential pressure instrument is based on a rugged and uncomplicated diaphragm movement, suitable for overpressure, partial vacuum and differential pressure measurements. The system’s operating principle is identical for all applications of this type. In a state of balance, forces of springs on both sides of diaphragm are balanced. The Pressure or differential pressure to be measured creates an unbalanced force of springs for measuring range until a new balance is reached. When subjected to excessive pressure, the diaphragm rests on metal supporting plates. A centre-mounted tappet transfers motion of the diaphragm system to indicator movement and to initiating elements of the microswitches.

General Specifications : 

  • Measuring range : 0… 400 mbar up to 0… 25 bar (see ordering code)
  • Nominal pressure : 25 bar
  • Max. static operating pressure : acc. to measuring range (see ordering code)
  • Max. pressure load : one-sided overpressure protected up to nominal pressure on (+) – and (-) side of diaphragm, partial vacuum protected
  • Perm. ambient temperature : -10… +70°C
  • Perm. medium temperature : 70°C
  • Protection class : IP 54 acc. to DIN EN 60529
  • Mounting position : as desired
  • Measuring accuracy  : ± 2.5% FS
  • Zero adjustment : located in the dial

Measuring System

  • Measuring ranges < 16 bar : diaphragm measuring system, diaphragm of fabric back stayed elastomer
  • Measuring range 0-25 bar : diaphragm measuring system, diaphragm of DURATHERM®

Switching Elements

  • Contact output : 1 or 2 microswitches, 1-channel change-over contacts
  • Adjustment of switching points : external adjustment by standard value scales smallest adjustable value: approx. 5% FS
  • Switching hysteresis : approx. 2.5% FS
  • Load data / contacts : U ~ max. = 250 V AC, I max. = 5 A, P max. = 250 VA
    U = max. = 30 V DC, I max. = 0.4 A, P max. = 10 W
  • Electrical Connection : numbered cable, prewired terminal box, 7-channel plug
  • Pressure Connection : thread G1/4 female, cutting ring connection for 6, 8, 10,12 mm tube of brass, zinced steel or chrome nickel steel connection shank G1/4 male DIN EN 837

Materials

  • Pressure chamber : aluminium GkAlSi10(Mg), varnished black
    aluminium GkAlSi10(Mg) HART-COAT® chrome nickel steel 1.4305
  • Measuring diaphragm : diaphragm measuring system and gaskets of NBR or Viton®, diaphragm of DURATHERM® NiCrCo-alloy
  • Materials: medium : stainless steel 1.4310, 1.4305
  • Materials: housing : macrolon
  • Weight : pressure chamber of Al = 1.2 kg, pressure chamber of 1.4305 = 3.5 kg
  • Mounting : pipe mounting, pressure connections = (+), (-) symbols
    • by screwed-in cutting ring or clamping ring connection
    • by screwed-in connection shank acc. to DIN EN 837 for nipple fitting acc. to DIN 16288
    wallmounting
    • 3 fastening elements

For more info Click here to access the datasheet

Refrigerant Gas Leak Detection for Safety

At ALVI India , we provide reliable sensors, controllers and warning devices for refrigeration leak detection.

Our product line PolyGard®2 ensures reliable monitoring of leakages at all times and thus protects not only the health of persons but also the operation of the refrigeration systems. The simple Plug & Play sensor technology (X-Change) also allows you to save time and costs for maintenance significantly. The sensors are available for all common refrigerants. Advantages when using our refrigerant leak detection system:

  • SIL2 compliant according to IEC 61508
  • Suitable for large and small systems
  • The X-Change exchangeable sensor makes calibration of the sensors easier
  • Alarm thresholds and interfaces are freely selectable

Continue reading “Refrigerant Gas Leak Detection for Safety”

CO+CO2 Multi-Gas-Controller MGC2

MSR, Germany Carbon Monoxide( 300 PPM) + Carbon dioxide (2000 PPM) Sensor transmitter, MSC2 in IP65 enclosure with following features:

Multi gas controller for toxic and combustible gases, refrigerants and oxygen.
Gas measuring, warning and monitoring controller based on state-of-the-art micro technology
for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants
or oxygen.
Internal function monitoring with integrated hardware watchdog, hardware and software according
to SIL2 compliant development process.
Easy sensor change or comfortable on-site calibration. Modular technology (plug-in and changeable),
reverse polarity protected, overload and short-circuit proof.
Three analog inputs (4-20 mA).
Three relays with changeover contact, potential-free max. 250 V AC, 5 A.
Two transistor outputs, 24 V DC, 0.1 A (plus switching).
Serial RS 485 interface with protocol for DGC06, also Modbus protocol as an option, display
depending on type and multicolor power LED

Continue reading “CO+CO2 Multi-Gas-Controller MGC2”

Silane Gas Data Logger Sensor

DESCRIPTION

Portable gas measuring device with integrated datalogger for the continuous monitoring of the ambient air to detect the presence of toxic gases and vapours, as well as of oxygen. Up to 16.000 measuring values are recorded in the datalogger.

APPLICATION

For the detection and recording of toxic gases and vapours, as well as of oxygen in a wide range of commercial applications. Standard housing FEATURES ƒ Suitable for toxic gases and vapours, as well as for oxygen ƒ Measuring cycle adjustable from 2 sec. to 5 hours ƒ Datalogger for 16.000 measuring values ƒ Data readout via the USB port ƒ Internal rechargeable battery: Lifetime according to sensor type ƒ Certified calibration

Continue reading “Silane Gas Data Logger Sensor”

Indoor Air Quality Sensor transmitter -IAQ

The most important aspect of air quality in closed rooms like homes, schools, recreational buildings, restaurants, public buildings, offices is the purity of air.

Stale or impure air reduces well-being and impairs productivity or efficiency of work procedures and production processes. The quality of air inside a building depends on the concentrations of contaminants and it is essential to monitor indoor air quality (IAQ) for occupant’s health, productivity and comfort.

Humans exhale CO2 when breathing. The more people you have in a small room for longer periods of time, the higher levels of CO2 you’re going to get. That is why CO2 measurements can be used to determine whether a building has appropriate ventilation. Or, to put it simply, if there’s enough fresh air coming inside to keep everyone healthy.

And while high CO2 levels can tell you when your rooms aren’t getting enough fresh air, high CO2 levels alone don’t cause discomfort, bad smells and health problems such as headaches that we feel when the air “gets bad”. The real cause is hidden in the build-up of contaminants when the air gets bad.

Here’s where measuring Volatile Organic Compounds (VOCs) comes in. VOCs are gases that are emitted in the air we breathe from different materials. Many commonly used products can be the sources of these compounds including building maintenance and cleaning products, paints, adhesives, sealants, carpets, drywall, and insulation materials, among others.

Continue reading “Indoor Air Quality Sensor transmitter -IAQ”

Level Measurement for Fuel Oil Tank

Why measure Fuel Oil Level?

Precise control of level measurement for fuel oil tank is crucial in many applications. In process plants fuel oil is delivered to the storage tanks and then is transferred to process or may be a smaller day tank. It is very important to know the fuel oil level either in the storage tank or in a day tank for day-to-day operations of the plants.

The main aspect for level measurement for fuel oil tank is to keep track of inventory in terms of volume. Keeping good control over your inventory has become increasingly important over the last several years. Level measurement is one key component for reliable and accurate inventory control. Many processes require a steady supply of inputs . A storage tank between the supply and process acts as a buffer and maintains steady and consistent supply for the process. For a maximum process efficiency the tanks need to be filled to full capacity at all times.

Continue reading “Level Measurement for Fuel Oil Tank”

Air Quality Monitoring – VOC Sensor Transmitter

The ADT-C3-1160 is designed for measuring and controlling
the indoor air quality (VOC) and the temperature in offices,
living spaces etc. It is also possible to control the indoor air
quality with three sequences (heating, ventilation, cooling
etc.).

FEATURES
 Measurement range: 0 – 4000 ppm VOC
 Internal automatic self-diagnostics with auto adjustment
 High accuracy, selectivity and reliability
 Automatic drift and temperature compensation
 Good resistance to poisoning
 Life expectancy > 10 years
 Maintenance interval > 5 years
 Reverse polarity protected, overload and short-circuit proof
 (0) 4 – 20 mA / (0) 2 – 10V analog signal output selectable
 IP65 protected
 Modular plug-in technology
 Approved according to EN 61010-1; ANSI/UL 61010 1; CAN/CSA-C22.2 No. 61010-1
 Serial interface RS-485 (optional)
 Manual addressing for RS-485 mode (optional)
 4 – 20 mA analog input for external transmitter (optional)
 Relay output (optional)
 Integrated buzzer (optional)
 LCD display (optional)
 Heating (optional)
 Duct mounting (optional)

For More Details Please Feel Free to Contact us:- info@alviautomation.com 01412293968

Sulphur Dioxide SO2 Sensor Transmitter ADT-53-1196

ALVI  Automation – India (http://www.alviautomation.com)  in association with Gas Alarm Systems – Australia (http://www.gasalarm.co.au) offer  Sulphur Dioxide SO2 Transmitter ADT-53-1196, For the detection of sulphur dioxide within a wide range of industrial and commercial applications.

APPLICATION:-

For the detection of sulphur dioxide within a wide range of industrial and commercial applications. Due to the standard analog signal and the RS-485 interface the SO2 transmitter is compatible to the PolyGard series MGC and DGC by MSR-E as well as to any other electronic control or automation system.
FEATURES:-
 Digital measurement value processing incl. temperature compensation.
 Continuous monitoring
 Low zero-point drift
 Poisoning stable
 Long life sensor
 Modular plug-in technology
 Easy maintenance
 Comfortable calibration with selective access release
 Reverse polarity protected, overload and short-circuit proof
 (0) 4 – 20 mA / (0) 2 – 10V analog signal output, selectable
 Serial interface RS-485
 IP65 protected Continue reading “Sulphur Dioxide SO2 Sensor Transmitter ADT-53-1196”