Gas Detection Solution For The Industrial Application

Protection Under Extreme Condition

industry

 

MSR-Electronic Protects Health and Plants Under Industrial Conditions.

In the chemical and Petrochemical Industry Permanent  Gas Monitoring and control solution of Rooms and Plants is very essential, In Which Explosive and toxic gas condition might occur in the atmosphere.

For the Protection of human beings constant monitoring of toxic and combustible gases and vapors is required, In addition, monitoring of lack of oxygen should be undertaken and oxygen surplus must be carried out.

MSR-Electronic offers a wide range of methods for detection of gases, On this basis MSR-Electronic develops individual gas sensors for industrial applications where extreme environmental conditions prevail.

Requirements for Gas Detectors

Standards and regulations in the commercial field

The products of MSR-Electronic comply with more than the general standards and regulations and can therefore guarantee the safety of the plant and human beings.

Wherever combustible or toxic substances are stored, bottled, processed or transported, the hazard potential caused by gases and vapors is particularly high. Correct planning and installation of gas detection system can, however significantly reduce the risks for humans and plants.

csm_px2_sensoren_1ca7c8fc4a

 

For more information Please contact us to info@alviautomation.com

Oxygen Sensor Transmitter For Hospital’s Oxygen Cylinder Storage Area

We are pleased to inform you all that recently we have supplied our product and service to  Eternal Heart Care Center (EHCC – Eternal Multispecialty Hospital Jaipur ), where we supplied MSR Oxygen Sensor Transmitter – MC2-D-E1195-A-3-0 and Oxygen Gas Leak Control and Display Alarm Panel  for there Oxygen and  NO Cylinder storage Room.

We are really happy to see there concern regarding the safety , as we all know that oxygen is flammable gas (supporter of  ignition) they install Oxygen leak detector and Control Alarm panel  in there premises for the safety purpose .

Installed Oxygen Sensor Transmitter having German Technology with high accuracy , long life, easy maintenance in economical price .

Oxygen (O2) gas detectors are used for  the detection of oxygen in rooms where changes of the oxygen concentration are possible, such as laboratories, hospitals and food process, cold storage and fruit ripening  industries etc.

MC2-D-E1195-A-3-0 have following features :

  • Measuring range: 0-25 Vol %
  • Sensor element: Electrochemical Diffusion
  • Analog output: 4 – 20 mA (or 2 – 10 V) analog output with selectable signal output
  • Accuracy: ± 0.5 Vol %
  • Response time: t90 ≤ 15 sec
  • Operating Voltage: 24VDC
  • Digital measurement value processing incl. temperature compensation
  • Internal function control with integrated hardware watchdog
  • Data / measured values in μC of the sensor unit
  • High accuracy, selectivity and reliability
  • Low zero point drift
  • Long life sensor
  • Hardware & software according to SIL2(Safety Integrity Level) compliant development process
  • Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration
  • Reverse polarity protected, overload and short-circuit proof
  • Housing for integration of the sensor unit
  • IP65 protected weatherproof enclosure with Features :
  • Rough rugged impact resistant polycarbonate protection
  • Glass fiber reinforced
  • Ultra violet protection
  • Hydrophobic filter

For more details and enquiry please feel free to contact us – Info@alviautomation.com 

For Technical Datasheet – Click Here

R-32 Refrigerant Gas Leak Detector Transmitter

We are pleased to introduce our one of best Refrigerant Sensor Transmitter R-32, R-22, R-125a, R-450a, R-404a, R-410a R23, R-508b, R-1234, R-452a, R-513a, and so on for more technical  details, datasheet and Refrigerants Sensor Transmitter  Please  Click  Here 

For any supermarket, food retailing and air conditioning is associated with refrigeration. Behind the refrigerator and display cases that keeps the food at a desired low temperature; is a huge network that has refrigerant piping, valves, joints, compressors, condensers and many other such components. The leak of refrigerant gas from such commercial refrigeration systems is a major maintenance cost for super market chains. Gas leaks can also have a considerable effect on the environment. Hence, Refrigerant Leak Detection in Supermarkets is very crucial.

Over the past few years, large supermarket chains have become increasingly aware of refrigeration systems in their stores. This has happened for a number of reasons, most notably because refrigeration is one of the largest costs when setting up and running a store and there are a number of ways in which the associated systems can be optimized to save money. Now, with the added pressures placed upon those who operate commercial refrigeration systems by environmental legislation, the optimization of refrigeration systems is more important than ever.

As might be expected, the presence of refrigerant gas in large, complex mechanical refrigeration system inevitably leads to the occasional leak. Refrigerant is quite expensive and can have detrimental effects if leaked into the atmosphere. It is therefore imperative that leaks from refrigeration systems be minimized, both from financial and environmental points of view. By not having an appropriate Refrigerant Leak Detection in Supermarkets, you could be running your equipment inefficiently, risking breakdowns and unknowingly leaking expensive gases.

Gas Alarm Systems offers a complete system with sensors, controllers and warning device for for continuous monitoring of almost all types of refrigerants. Our sensors and controllers are easy to install and calibrate. The sensors detect the refrigerant gas in a particular range and depending upon the requirement can be configured for an analog or a digital output and triggers an alarm at a preset level. By recording the data around leak events, retailers can identify the problem areas. If such leak goes undetected it could degrade the refrigeration’s capacity to maintain proper cooling. Alarms are essentially warnings of such adverse conditions. Trained personnel can take action and call the appropriate store staff or maintenance personnel to avert situations where stock may be endangered.

Incorrect refrigerant handling can be very expensive through loss of energy efficiency, expensive refrigerant leakage and the risk of a catastrophic refrigerant leak. Installing Refrigerant Leak Detection in supermarkets  protects property and environment.

For further information, please contact us.

Ammonia Sensor Detector Transmitter – MC2-X-S2125-X

We are pleased to introduce our one of best and new series of Ammonia Detector (Ammonia Sensor Transmitter ) which is very Economical in price having high accuracy, long life and fast response time and many more advance features .

Ammonia is a Toxic, colorless and pungent smelling gas which affect living bodies,  to stop any hazardous and panic incident we must use Ammonia Gas Leak Detection – Ammonia Sensor Transmitter in the area where ammonia gas or gas container present.

Exposure to high concentrations of ammonia in the air causes immediate burning of the eyes, nose, throat and respiratory tract and can result in blindness, lung damage or death. Inhalation of lower concentrations can cause coughing, and nose and throat irritation to stop all these panic incident we need to use Ammonia Detector Transmitter in the place where there is a chance of leakage of NH3 ammonia gas.

This Ammonia Detector detects the leakage of ammonia gas and immediately and Transmit the signal to actuate the alarm and close the ammonia gas supply line.

Silent Features of MSR Ammonia Sensor Transmitter 

  • Measuring Range Available : 0-1000 PPM.
  • Gas Type: NH3 Ammonia
  • Sensor Cell: Semiconductor
  • Operating Voltage: 24 VDC
  • Output Signal: 4-20 mA or 2-10 VDC
  • Response time T90 < 30 Sec
  • Housed in an IP65 polycarbonate Enclosure
  • Coverage area: 80-120 Sqm
  • Housing UL94 V2 approved
  • Wall mount housing
  • Calibration interval: 12 month
  • Continuous Monitoring
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Long life sensor
  • Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration
  • Software according to SIL2 compliant development process

For more details please contact us –  Info@alviautomation.com

For the technical datasheet – Click Here

Carbon Monoxide Sensor Transmitter – Best Technology in Economical Price

GasAlarm – GAS-CO-300-D  carbon Monoxide Sensor Transmitter is one of the Best CO Sensor Transmitter this time present in market having Best German Technologies, having all the advanced features,  high accuracy in very economical cost price .

#Long_Life #High_Accuracy #Economical_price #Advance_Features #German_Technologies   #Maximum_Coverage

Introducing the GasAlarm Systems GAS-CO-300-D

Most cost optimum sensor transmitter for carbon monoxide – application in car park ventilation fan control, coal mining, coal handling plant, coal washeries, boilers, steel plants, pharmaceutical anywhere gas and coal combustion take place – best very early fire detection due to gas radicals detection – smoldering fires.

 

Specifications in Detail:

  • 24VDC power with 4-20mA output (current loop)
  • 0-300PPM Carbon Monoxide measuring range
  • Long Life – ≥ 6 years (Life Expected  ≥  10 years)
  • High Accuracy –  ± 3ppm
  • Wiring – 2 wire system (reduce wire cost)
  • Onboard potentiometer for “zero” adjustment
  • Onboard potentiometer for “gain/span” adjustment
  • Multimeter connections for measurement during calibration
  • With “D” enclosure option, rated at IP65
  • Calibration Interval – 12 Months
  • Easy to use with low maintenance cost.

Click here to download the datasheet

For more query and enquiry please contact us: Info@alviautomation.com 

PNG Gas Leak Detector

PNG (Methane), chemically known as CH4 is highly flammable, lightweight gas with LEL at 5% Vol = 100% LEL.

Methane gas detector series is highly robust, industrial grade, flameproof or explosion proof gas detector for methane leakage detection or LEL monitoring. Methane is also available in form as a natural gas, pressurized natural gas (PNG), liquefied natural gas (LNG).

IMG_20171228_114953395

csm_Bild_MC2_5m_4_klein_e9875bc76f

The detector is used for online, continuous monitoring of the flammable concentration of methane in %LEL or %Vol terms in ambient air or in duct or pipeline. It is ATEX, IECEX, PESO certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

IMG_6319fg

The sensor transmitter offers linear, proportional analog output in industry standard current signals, over measuring a range of 0 ~ 100 % LEL (lower explosive limit). The detector works on highly sensitive catalytic bead-based pellistor sensor cell, with low response time. It has the unique feature of an auto diagnostic watchdog with zero point tracking feature. Due to its 12-bit microprocessor based control unit, it offers high accuracy over the long term. The detector is also equipped with a sintered filter with flashback arrestor for enhanced safety.

It also offers optional features like inbuilt LCD display, flashing alarm LEDs, onboard potential free relay contacts (24VDC @ 1 A), RS485 serial interface with Modbus RTU communication.

IMG_6325

Technical Specifications:

  • Measuring Parameters: LEL level or leakage detection – methane, LNG, PNG, natural gas
  • Sensor Technology: Catalytic bead-based pellistor sensor cell
  • Measuring range: 0 ~ 100 % LEL ( 0 ~ 5% vol)
  • Response time (t90): < 10 sec
  • Control unit: 12-bit microprocessor based
  • Auto zero point tracking for drift compensation
  • Power supply: 24 VDC
  • Ingress protection: IP65, IP 66, IP68
  • Enclosure: Stainless steel (for sensor cell), anti-static epoxy coated metal alloy (for transmitter), polycarbonate
  • Output: linear, proportional 4-20mA
  • Mounting: wall, duct, pipeline
  • Safety integrity level: SIL 2
  • Optional: LCD Display, alarm LEDs, potential free relay contacts
  • Hazardous area: Zone 1, 2
  • Commercial areas: Kitchen, store room, pine line

Application:

  • Coal mines, underground mines
  • Oil & gas, refinery
  • Fertilizer industry
  • PNG/city gas distribution system
  • PNG / LNG automobile gas filling stations
  • Landfill Gases
  • Sewage treatment plants (STP), effluent treatment facility
  • Cryogenic application
  • Chemical, petrochemical industry
  • Food processing industry
  • Furnace, burner application
  • Gas reticulation system

For more details please drop us a  mail at info@alviautomation.com or contact us

You can also visit our new online product portal for various commercial and industrial application www.alviautomation.in

 

CO Detector – Perfect CO Detector For Car Park Ventilation & Fan Control

We  ALVI Automation India Private Limited in association with  GasAlarm Systems  Australia (www.gasalarm.com.au) and MSR Germany, specializing in gas detection & monitoring solutions feel pleased to say that we had done lots of successful car park ventilation system projects  all over India as well as in  Australia, Newziland, Sri Lanka, Myanmar, Canada, UAE, and many more countries and found our Carbon Monoxide Sensor Transmitter  GAS-CO-300-D and MSR CO Sensor Transmitter  MA-0-1110-F-B is the best energy saving, accurate, fast responsive, long life and  economical in cost compared to the other brands present in market .

Introducing the GasAlarm Systems GAS-CO-300-D

Most cost optimum sensor transmitter for carbon monoxide – application in car park ventilation fan control, coal mining, coal handling plant, coal washeries, boilers, steel plants, pharmaceutical anywhere gas and coal combustion take place – best very early fire detection due to gas radicals detection – smoldering fires.

 

Specifications in Detail:

  • 24VDC power with 4-20mA output (current loop)
  • 0-300PPM Carbon Monoxide measuring range
  • Long Life – ≥ 6 years (Life Expected  ≥  10 years)
  • High Accuracy –  ± 3ppm
  • Wiring – 2 wire system (reduce wire cost)
  • Onboard potentiometer for “zero” adjustment
  • Onboard potentiometer for “gain/span” adjustment
  • Multimeter connections for measurement during calibration
  • With “D” enclosure option, rated at IP65
  • Calibration Interval – 12 Months
  • Easy to use with low maintenance cost.

Click here to download the datasheet

For more query and enquiry please contact us: Info@alviautomation.com 

ATEX, IECEX, SIL2, PESO Certified Hydrogen Gas Detector online LEL monitor for Zone1

Hydrogen sensor transmitter for online, continuous LEL or flammability detection in battery rooms, UPS rooms, cracking plants, hydrogenation plants, hydrogen gas bank etc. The detector is explosion proof ATEX, IECEX certified with SIL 2 safety level and suitable for installation in hazardous area Zone 1 and Zone 2.

It is available with LCD Display, onboard relay contacts, flashing alarm LEDs, auto diagnostic watch dog, non-intrusive calibration, with industry standard linear analog output.

Hydrogen sensor transmitter / detector – explosion proof, ATEX, Zone 1

online, continuous monitoring of hydrogen LEL or flammability level, wall or duct mount, with / without display & relays, ATEX certified with safety integrity level SIL 2, explosion proof for Zone 1, 2
pdf download icon
Model no: PX2-X-X-3440-XX 

Hydrogen gas detector, PX2 series is highly robust, industrial grade, flameproof or explosion proof gas detector for hydrogen LEL or flammability monitoring. It is used for online, continuous monitoring of hydrogen flammable concentration in %LEL or %Vol terms in ambient air or in duct or pipeline. It is ATEX Ex’d’ and Ex’n’ certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.
Explosion proof or flameproof gas sensor transmitter - ATEX, Zone 1, 2 for all toxic, flammable gas, oxygen
The sensor transmitter offers linear, proportional analog output in industry standard current signals, over measuring range of 0 ~ 100 % LEL (lower explosive limit). The detector works on highly sensitive catalytic bead based pellistor sensor cell, with low response time. It has unique feature of auto diagnostic watch dog with zero point tracking feature. Due to its 12-bit microprocessor based control unit, it offer high accuracy over long term. The detector is also equipped with sintered filter with flashback arrestor for enhanced safety

IMG_6319fg

 

Hydrogen sensor transmitter – LEL detector, ATEX Zone 1,2 flameproof, with / without display

It also offers optional features like inbuilt LCD display, flashing alarm LEDs, onboard potential free relay contacts (24VDC @ 1 A), RS485 serial interface with Modbus RTU communication.

Key Features:

  • Catalytic bead based Pellistor sensor cell with low flash energy
  • 12-bit microprocessor control unit
  • Non-intrusive one man calibration via hall effect switches
  • ATEX, PESO, IEXEC, SIL2 certified explosion proof / flameproof, suitable for Zone 1, 2 gas explosion installation
  • Linear, proportional analog industry standard current output
  • Continuous system self-diagnosis with watch dog
  • Flashback arrestor with sintered filter
  • Auto Zero point tracking to zero point compensation
  • SIL 2 HW TUV certified
  • RS485 serial interface with Modbus RTU communication (optional)
  • 2 relay output module (optional)
  • System and alarm LED indicators (optional)
  • Modbus RTU communication over RS485 serial interface

PX2 Hazadous Gas DetectorIMG_6322 IMG_6325 IMG_6302

Hydrogen sensor transmitter – Flameproof, ATEX for Zone 1, 2 LEL monitor with catalytic sensor

Technical Specifications:

  • Measuring Parameters: hydrogen gas flammability or leakage
  • Sensor Technology: Catalytic bead based pellistor sensor cell
  • Measuring range: 0 ~ 100 % LEL ( 0 ~ 4% v/v @ STP)
  • Response time (t90): < 20 sec
  • Control unit: 12 bit microprocessor based
  • Auto zero point tracking for drift compensation
  • Power supply: 24 VDC
  • Ingress protection: IP66
  • Enclosure: Stainless steel (for sensor cell), anti-static epoxy coated metal alloy (for transmitter)
  • Output: linear, proportional 4-20mA
  • Mounting: wall, duct, pipeline
  • Safety integrity level: SIL 2
  • ATEX marking: CE 722 Ex II 2G EEx d IIC T6, CE 722 Ex II 3G EEx nA IIC T6
  • Optional: LCD Display, alarm LEDs, potential free relay contacts
  • Hazardous area: Zone 1, 2

Application:

  • Oil & Gas, Petrochemical, refinery
  • Battery rooms, UPS facility
  • Mobile switching center (MSC) of cellular / telecom site
  • Cracking plants
  • Hydrogenation plants
  • Chemicals
  • Cold stores
  • Pharmaceuticals, medicinal formulation

For more Information please contact us or mail us info@alviautomation.com 

Acetic Acid Gas Leak Detector with flameproof, PESO, IEC-Ex and ATEX Zone 1, 2

Acetic acid gas detector for online, continuous detection of acetic acid vapour presence or LEL level in ambient air or ducts. The detector is explosion proof ATEX certified with SIL 2 safety level and suitable for installation in hazardous area Zone 1 and Zone 2. The instrument can be installed at solvent storage facility, paint booth, refinery, paint manufacturing units, cleansing facility at textile manufacturing etc.

It is available with LCD Display, on-board relay contacts, flashing alarm LEDs, auto diagnostic watch dog, non-intrusive calibration, with industry standard linear analog output.

Model: XT21-34XX-PXX-XXX
pdf download icon

SMART MSR-Sensitron series acetic acid gas or vapour sensor is highly robust, industrial grade, flameproof or explosion proof instrument for LEL concentration detection. The instrument can be installed for flammability level or LEL detection of acetic acid gas in all industrial and commercial area eg. chemical plant, fertilizer, solvent manufacturing unit, printing press, paint booth etc

The detector can be installed at walls, surfaces or in ducts for monitoring in gas or air sample. It is ATEX EEx’d’ certified with SIL 2 safety integrity level for hazardous area installation Zone 1 and 2.

The sensor transmitter offers linear, proportional analog output in industry standard current signals, over measuring a range of 0 ~ 100 % LEL (lower explosive limit). The detector works on highly sensitive catalytic bead-based pellistor sensor cell, with low response time. It has unique feature of an auto diagnostic watchdog with zero point tracking feature. Due to its 10-bit microprocessor based control unit, it offers high accuracy over the long term. The detector is also equipped with a sintered filter with flashback arrestor for enhanced safety.

IMG_6319fgPX2 Hazadous Gas Detector

It also offers optional features like inbuilt LCD display, flashing alarm LEDs, onboard potential free relay contacts (24VDC @ 1 A), RS485 serial interface with Modbus RTU communication.

Key Features:

  • Non-intrusive one man calibration via Hall effect switches
  • 4-digit display and 5 mode status LEDs
  •  Standard 4-20 mA 3 wire output
  •  Standard 1 relay output
  •  Optional 3 relay output card
  •  Optional RS485 interface for Modbus communication.
  •  Zero tracking to maintain the zero point steady from possible drifts
  •  Ongoing system self diagnosis
  •  ATEX II2G Ex db IIC T5 Gb (standard marking) (II2 GD with optional adapter)
  •  ATEX II2G Ex db [ib] IIC T6 Gb for detectors with intrinsically safe protection
  •  SIL 2HW tested, SIL3 SW pending
  • Wide range of sensors and detectable gases
  • Wide range of accessories for installation and maintenance
  •  Easy sensor replacement

IMG_6302IMG_6322

Acetic acid gas sensor – analog transmitter for LEL monitoring, Zone 1, SIL 2 safety, ATEX certified, flameproof

Technical Specifications:

  • Measuring Parameters: LEL or flammable concentration of acetic acid vapour / gas
  • Sensor Technology: Catalytic bead based pellistor sensor cell
  • Measuring range: 0 ~ 100 % LEL
  • Response time (t90): < 30 sec
  • Control unit: 10 bit microprocessor based
  • Warm up time: < 5 mins
  • Auto zero point tracking for drift compensation
  • Power supply: 24 VDC
  • Ingress protection: IP65
  • Enclosure: Stainless steel (for sensor cell), anti-static epoxy coated metal alloy (for transmitter)
  • Output: linear, proportional 4-20mA
  • Mounting: wall, duct, pipeline
  • Safety integrity level: SIL 2
  • ATEX marking:
    • CE 722 Ex II 2G EEx d IIC T6
    • CE 722 Ex II 3G EEx nA IIC T6
  • Optional: LCD Display, alarm LEDs, potential free relay contacts
  • Hazardous area: Zone 1, 2

Application:

  • Fertilizer & chemical industry
  • Oil & gas, refinery
  • Solvent and paint unit
  • Paint booth
  • Explosive manufacturing

 

For more information please contact us or mail us at info@alviautomation.com

 

Ammonia Gas Leak Detection – Ammonia Sensor Transmitter

Ammonia is a Toxic, colorless and pungent smelling gas which affect living bodies,  to stop any hazardous and panic incident we must use Ammonia Gas Leak Detection – Ammonia Sensor Transmitter in the area where ammonia gas or gas container present.

Exposure to high concentrations of ammonia in the air causes immediate burning of the eyes, nose, throat and respiratory tract and can result in blindness, lung damage or death. Inhalation of lower concentrations can cause coughing, and nose and throat irritation to stop all these panic incident we need to use Ammonia Detector Transmitter in the place where there is a chance of leakage of NH3 ammonia gas.

This Ammonia Detector detects the leakage of ammonia gas and immediately and Transmit the signal to actuate the alarm and close the ammonia gas supply line.

Silent Features of MSR Ammonia Sensor Transmitter 

  • Measuring Range Available : 0-100, 0-300, 0-500 PPM
  • Gas Type: NH3 Ammonia
  • Sensor Cell: Electrochemical Diffusion
  • Operating Voltage: 24 VDC
  • Output Signal: 4-20 mA or 2-10 VDC
  • Response time T90 < 120 Sec
  • Housed in an IP65 polycarbonate Enclosure
  • Coverage area: 80-120 Sqm
  • Housing UL94 V2 approved
  • Wall mount housing
  • Calibration interval: 12 month
  • Continuous Monitoring
  • High accuracy, selectivity, and reliability
  • Low zero point drift
  • Long life sensor
  • Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration
  • Software according to SIL2 compliant development process

For more Technical Details please click – Datasheet 

Oxygen Sensor Transmitter – MC2-D-E1195-A-3-0

We are pleased to introduce Oxygen Sensor Transmitter – MC2-D-E1195-A-3-0,  German Technology with high accuracy , long life, easy maintenance in economical price .

Oxygen (O2) gas detectors are used for  the detection of oxygen in rooms where changes of the oxygen concentration are possible, such as laboratories, hospitals and food process, cold storage and fruit ripening  industries etc.

MC2-D-E1195-A-3-0 have following features :

  • Measuring range: 0-25 Vol %
  • Sensor element: Electrochemical Diffusion
  • Analog output: 4 – 20 mA (or 2 – 10 V) analog output with selectable signal output
  • Accuracy: ± 0.5 Vol %
  • Response time: t90 ≤ 15 sec
  • Operating Voltage: 24VDC
  • Digital measurement value processing incl. temperature compensation
  • Internal function control with integrated hardware watchdog
  • Data / measured values in μC of the sensor unit
  • High accuracy, selectivity and reliability
  • Low zero point drift
  • Long life sensor
  • Hardware & software according to SIL2(Safety Integrity Level) compliant development process
  • Easy maintenance and calibration by exchange of the sensor unit or by comfortable on-site calibration
  • Reverse polarity protected, overload and short-circuit proof
  • Housing for integration of the sensor unit
  • IP65 protected weatherproof enclosure with Features :
  • Rough rugged impact resistant polycarbonate protection
  • Glass fibre reinforced
  • Ultra violet protection
  • Hydrophobic filter

For more details and enquiry please feel free to contact us – Info@alviautomation.com 

For Technical Datasheet – Click Here

Best Carbon Monoxide (CO) Sensor Transmitter

Best Carbon monoxide(CO) and Very early smoke & fire Sensor (VEFSA) Transmitter having benefits of High Accuracy, Long Life, in  Budgetary  Price .

Better monitor CO and CO+ radicals  which will solve the purpose of fire & Smoke monitoring as well as CO monitoring.

Best Uses for  :-

  • Carbon Monoxide with enhanced CO radical detection capability
  • Very early smouldering fire and smoke detection
  • VESFA system (very early smoke and fire alarm)
  • Parking area, garages, chillers rooms and heating, as well as dusty & humid area like pharmaceuticals, coal mine, conveyor belt, cement plant,coal yard, thermal power plants, flour mills, powder industries etc.

specifications:

  • Make :  MSR Germany  (Made in Germany)
  • Sensor Model: MA-0-1110-F-B
  • Measuring Gas: Carbon Monoxide, Enhanced CO+ radicals
    Detection.
  •  Sensor element (cell): Electrochemical Diffusion, Electrolyte type Gel Based (no leak, no membrane rapture, no orientation problem & no false alarm )
  • Plug in type Sensor transmitter. (Easy maintenance, easy returnable in case of any fault in sensor or transmitter)
  • Measuring Range: 0-300 ppm (Standard)
  • Quick response and fast recovery to Zero
  • Poisoning Stable.
  • Over flooding protection
  • Connection: Two wire sensor.
  • Accuracy: ± 3 ppm.
  • Repeatability:
  • Response time T90:- ≤ 50 Seconds.
  • Warm up time (First Time):- ≤ 3 Min.
  • Protection Class: IP 44 Enclosure (Good for indoor application), Also available in IP54 and IP65 Enclosure (For outdoor application)
  • Stability & resolution:≤ 50 Seconds.
  • Sensor life expectancy: ≥ 5 years (Site feedback ≥ 10 years)
  • Calibration Interval : Yearly
  • Sensor Coverage Area:700 m2 to 750m2 (depends upon the country specific parking ventilation standards.)
  • Analog output signal : Standard: 4-20 mA Linear Output (2-10 Vdc)

For more details and query Please contact us : info@alviautomation.com

For the technical datasheet please click here : Datasheet

Carbon Monoxide (CO) Detector – Best German Technology

We are pleased introduce  Carbon Monoxide (CO) Detector – Best German Technology  in most economical cost compare to the  market price of other competitor brand .

As we all know that Carbon Monoxide  gas is also called silent – invisible killer as CO doesn’t have smell, colour  or tase .

Any time you burn something—like gasoline, natural gas, wood, oil, propane, or charcoal—carbon monoxide is released into the air. In outdoor spaces, this usually isn’t a health hazard because there is enough area for the CO to dissipate, so particles never amount to a toxic level. The danger comes when carbon monoxide is released in a contained area like your home, RV, or garage, Car Park, Coal Mines, Industries.

It is most important for everyone to install CO detector in their premises as mentioned above it is best security system of their life and property as CO detector can also intimate you if there is any fire in the premises .

For any enquiry or query please feel free to contact us  in  our mail id – info@alviautomation.com

Hydrogen / Flammable Gas monitoring system in battery, inverter charging room – to prevent explosion

ALVI Automation also trading as GasAlarm in association with ALVI Technologies Sydney Australia brings to you a complete Automation solution along with the best selling product in terms of quality and reliability MSR GmbH Hydrogen sensor transmitter.

Hydrogen sensor transmitter specifications:

  • Should have Catalytic (pellistor) based sensor cell, with catalytic bead
  • Should have a measuring range of minimum 0-100% LEL (lower explosive limit) for flammability monitoring, with no poisoning effect of background gases
  • Should have a catalyst capable of providing flashing point, at a lower temperature, for the sensor cell.
  • Should have microprocessor-based value processing with temperature, vibration, moisture, humidity etc compensation reading
  • Should have high accuracy, high repeatability, high reliability
  • Should be a 3-wire connection for power supply and signal output.
  • Should have jumper selectable analog output: 0-10V, 2-10V, 0-20mA, 4-20mA
  • Should have linear and proportional signal output.
  • Should have low response time: t50 < 3 s; t90 < 10 s /methane
  • Should have Low voltage operation: 24V AC / DC
  • Should have low power consumption: 35 mA, max. (0.85 VA)
  • Should be wall mountable without need of further mounting brackets etc.
  • Should have replaceable sensor cell and PCB for easy service and replacement
  • Should have life expectancy of > 3 years, replaceable sensor cell
  • Should capable of mounting in any direction, with no effect on performance, output and life of these sensors (no orientation problems)
  • Should have poisoning protection, against background gases, lead vapours, dust etc
  • Should have overflooding protection
  • Should have reverse polarity and short circuit protection
  • Should capable for field calibration
  • Should have minimum IP65 protection
  • Should have vibration protection (High frequency, low amplitude) and knock protection (high amplitude, low frequency)
  • Should have fast response time
  • Should have IMMUNITY TO RF/FM INTERFERENCE as per the guidelines of EMC- Directive 2004/ 108/ EEC
  • Should be Approved according to EN 61010-1; ANSI/UL 61010 1; CAN/CSA-C22.2 No. 61010-1
  • Should have Digital method  for calibration
  • Should have enclosure flammability in accordance to UL 94 V2

Smart Central monitoring cum control system:

 

  • Should be based on PLC or microprocessor based system with pre-defined logic retention capacity.
  • Should have LCD Display
  • Should be able to expand analog input channel with help of slave or expansion module. No need to replace or change whole monitoring system
  • should have free configurable set points at every channel input
  • Should have the facility to temporary disable any channel with a key press, for maintenance mode etc.
  • Should have sufficient potential free (230VAC, 5A) relays. Should able to expand the number of relays with help of slave/expansion modules.
  • Relays should capable of the soft program, with one-to-one, one-to-many, many-to-one configuration with any channel set-points.
  • Should be provided with contactor arrangement for operation, protection of exhaust fans, etc
  • Should have overload protection arrangement
  • Should have fault LED
  • Auto-diagnostic watchdog with built-in error code, fault LED indication informing about the type of system error/fault
  • Should have a password for protection against any unauthorized system access.
  • Simple English Menu driven (system error, status alarm, status relay, MP parameter etc)
  • Configurable relay parameters: energized, de-energized, latching, non-latching
  • Should have provision/option for BMS integration via a digital network.

20171101_182913

Control & warning logic:

H2 concentration Action
0-15% LEL No action. Display readout
>25% LEL (or as advised by the client) Start exhaust system (to reduce gas concentration)
> 50% LEL (or as advised by the client) Switch on Flasher & Alarm system (to start evacuation)

For more details please contact us or mail us at info@alviautomation.com 

Carbon monoxide monitoring & control system for parking ventilation

 Carbon monoxide and Very early smoke & fire sensor (VEFSA) transmitter

(Better monitor CO and CO+ which will solve the purpose of fire & Smoke monitoring as well as CO monitoring)

specifications:

  • Should be capable of detection, measurement and monitoring of carbon monoxide and Carbon monoxide gas radicals
  • Should have Electro-chemical type sensor cell
  • Should have Gel based Electrolyte in the sensor cell
  • Should have 0-300ppm measuring range, taking care over-rangenge detection.
  • Should have high accuracy, high repeatability , high reliability
  • Should have a coverage area of 700-750 m2
  • Should a be 2-wire loop powered connection for power supply and signal output.
  • Should analog output: 4-20mA (standard), 2-10V (3-wire loop) (optional)
  • Should have linear, proportional
  • Should have low response time: T90 < 50 sec
  • Should have accuracy of ≤ 3% of measuring range.
  • Should have low warm up time, ≤ 3 mins
  • Should have Low voltage operation: 24V AC / DC
  • Should have low power consumption: 22 mA, max. (0.6 VA)
  • Should not be cross-sensitive to gases like SO2, acetone, ammonia, Carbon dioxide, Nitrogen dioxide, Nitric oxide.
  • Should be wall mountable without need of further mounting brackets etc.
  • Should have plug-in, easy replaceable sensor cell (simple push – pull arrangement) and PCB for easy service and replacement (no need to change the whole unit)
  • Should have auto recovery to zero point
  • Should have life expectancy of > 5 years, replaceable sensor cell
  • Should capable of mounting in any direction, with no effect on performance, output and life of these sensors (no orientation problems)
  • Should have poisoning protection, against background gases, lead vapours, dust etc
  • Should have overflooding protection
  • Should have reverse polarity and short circuit protection
  • Should have manual trimpot calibration facility, with annual calibration frequency
  • Should capable for field calibration
  • Should have atleast IP44 protected housing, with the provision of dust and moisture protection with hydrophobic filter arrangement.
  • Should have fast response time
  • Should have IMMUNITY TO RF/FM INTERFERENCE as per the guidelines of EMC- Directive 2004/ 108/ EEC, CE
  • Should have enclosure flammability in accordance to UL 94: VO

Central monitoring cum control system:

  • Should be based on PLC or microprocessor based system with pre-defined logic retention capacity.
  • Should have LCD or LED Display
  • Should be able to expand analog input channel with help of slave or expansion module. No need to replace or change whole monitoring system
  • should have free configurable set points at every channel input
  • Should have facility to temporary disable any channel with key press or control device, for maintenance mode etc.
  • Should have sufficient potential free (230VAC, 5A) relays. Should able to expand number of relays with help of slave / expansion modules.
  • Relays should be capable of soft program, with one-to-one, one-to-many, many-to-one configuration with any channel set-points.
  • Should be provided with contactor arrangement for operation, protection of exhaust fans, etc
  • Should have overload protection arrangement
  • Should have fault LED
  • Auto-diagnostic watchdog with built in error code, fault LED indication informing about the type of system error/fault
  • Should have password for protection against any un-authorised system access.
  • Simple English Menu driven (system error, status alarm, status relay, MP parameter etc)
  • Configurable relay parameters: energized, de-energized, latching, non-latching
  • Should have provision / option for BMS integration via digital network.

Control & warning logic: 

CO concentration Action
0-35 ppm No action. Display readout
>35ppm Start fresh air & exhaust system (to reduce gas concentration) (lower speed)
> 60ppm Start fresh air & exhaust system (higher speed)

 

Control & warning logic: (with CO and CO+ monitoring for CO, fire and smoke )

CO concentration Action
0-35 ppm No action. Display readout
>35ppm Start fresh air & exhaust system (to reduce gas concentration) (lower speed)
> 60ppm Start fresh air & exhaust system (higher speed)
>200ppm Send signals to fire alarm system and stop fresh air system

Click here to download CO, Co+ datasheet

Click here to download controller datasheet

For more details pleae feel free to contact us  or visit www.alviautomation.com